• Shopping Cart
    There are no items in your cart

AS/NZS 3131:1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Approval and test specification - Plugs and socket-outlets for use in installation wiring systems

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Superseded by

AS/NZS 3131:2001

Language(s)

English

Published date

05-09-1995

€77.79
Excluding VAT

1 - AS / NZS 3131:1995 APPROVAL AND TEST SPECIFICATION - PLUGS AND SOCKET-OUTLETS FOR USE IN INSTALLATION WIRING SYSTEMS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.2.1 General requirements of AS 3100
6 - 1.2.2 Specific requirements of this Standard
6 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.4.1 Non-rewirable plug
7 - 1.4.2 Plug
7 - 1.4.3 Rewirable plug
7 - 1.4.4 Socket-outlet
7 - 1.5 MEANS OF RETENTION OF A PLUG AND SOCKET-OUTLET
8 - SECTION 2 PLUGS
8 - 2.1 TERMINALS AND INTERNAL CONNECTIONS
8 - 2.1.1 Materials
8 - 2.1.2 Construction of terminals
8 - 2.2 PLUG PINS
8 - 2.2.1 Materials
8 - 2.2.2 Assembly of pins
8 - 2.2.3 Form of pin
8 - 2.3 INSULATING MATERIALS
9 - 2.4 NON-REWIRABLE PLUGS
9 - 2.5 METHOD OF ENTRY AND ANCHORAGE FOR CABLE, FLEXIBLE CABLE OR FLEXIBLE CORD
9 - 2.6 STRENGTH OF SCREW THREADS AND FIXINGS
9 - 2.7 RATING AND DIMENSIONS
9 - 2.7.1 General
9 - 2.7.2 Compliance with dimensional requirements of Appendix A
9 - 2.8 INTERNAL CONNECTIONS
9 - 2.9 FUSES
10 - 2.10 MARKING
10 - 2.10.1 Required marking
10 - 2.10.2 Location of marking
10 - 2.10.3 Additional requirements for rewirable plugs
10 - 2.10.4 Earthing connections
10 - 2.10.5 Live connections
10 - 2.10.6 Marking sequence of pins
10 - 2.11 IP DESIGNATED PLUGS
10 - 2.12 TESTS ON PLUGS
10 - 2.12.1 General
11 - 2.12.2 Mechanical tests
11 - 2.12.3 Insulation resistance test
11 - 2.12.4 High voltage test
12 - 2.12.5 Determination of ignitability and combustion propagation
12 - 2.12.6 Resistance to tracking
12 - 2.12.7 Heat behaviour
13 - SECTION 3 SOCKET-OUTLETS
13 - 3.1 TERMINALS AND INTERNAL CONNECTIONS
13 - 3.1.1 Material
13 - 3.1.2 Construction of terminals
13 - 3.2 SOCKET-OUTLET CONTACTS
13 - 3.2.1 Material
13 - 3.2.2 Construction
13 - 3.3 INSULATING MATERIALS
13 - 3.4 STRENGTH OF SCREW THREADS AND FIXINGS
13 - 3.5 RATING AND DIMENSIONS
13 - 3.5.1 General
14 - 3.5.2 Compliance with the dimensional requirements of Appendix A
14 - 3.6 ARRANGEMENT OF EARTHING CONNECTIONS
14 - 3.7 PREVENTION OF CONTACT WITH LIVE PINS
14 - 3.7.1 During normal insertion
14 - 3.7.2 During other than normal insertion
14 - 3.7.3 Alignment of covers
14 - 3.8 PROHIBITED ARRANGEMENTS
14 - 3.8.1 Fuses
14 - 3.8.2 Other wiring systems
14 - 3.9 SWITCHES
14 - 3.10 FLOOR SOCKET-OUTLETS
14 - 3.11 MARKING
14 - 3.11.1 Required marking
15 - 3.11.2 Location of marking
15 - 3.11.3 Earthing connections
15 - 3.11.4 Live connections
15 - 3.11.5 Marking sequence of connections
15 - 3.12 IP-DESIGNATED SOCKET-OUTLETS
15 - 3.13 TESTS FOR SOCKET-OUTLETS
15 - 3.13.1 General
15 - 3.13.2 Mechanical tests
16 - 3.13.3 Insulation resistance Test No. 1
16 - 3.13.4 High voltage test
16 - 3.13.5 Test of temperature rise No. 1
17 - 3.13.6 Current breaking test
17 - 3.13.7 Test of temperature rise No. 2
17 - 3.13.8 Insulation resistance Test No. 2
17 - 3.13.9 Test of earthing connection
17 - 3.13.10 Withdrawal force test
18 - 3.13.11 Determination of ignitability and combustion propagation
18 - 3.13.12 Resistance to tracking
18 - 3.13.13 Heat behaviour
19 - APPENDIX A - RATINGS, DIMENSIONS, KEYWAY LOCATIONS AND MEANS OF RETENTION
19 - A1 GENERAL
19 - A2 CONFIGURATIONS

Specifies essential safety requirements for plugs and socket-outlets for use in installation wiring systems for approval and test purposes. In Australia, This Standard is intended to be read in conjunction with AS 3100.

Committee
EL-004
DocumentType
Standard
ISBN
0 7262 9764 X
Pages
34
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard applies to plugs and socket-outlets having current ratings not exceeding 40 A, intended for indoor use, and at voltages not exceeding 500 V a.c., for the purpose of enabling connection and disconnection at will of the wiring system of an installation. Standardized configurations are given in Appendix A. This Standard also applies to plugs and socket-outlets used for removable partitions and for the connection of stationary equipment.This Standard does not apply to the following:(a) Appliance couplers for household and similar general purposes within the scope of AS 3109.1.(b) Plugs and socket-outlets within the scope of AS/NZS 3112.(c) Cord extension sockets within the scope of AS/NZS 3120.(d) Socket-outlet adaptors within the scope of AS/NZS 3122.(e) Plugs, socket-outlets and couplers for general industrial application within the scope of AS/NZS 3123.NOTES:This Standard may be applied to configurations and contact types other than those depicted herein providing all appropriate (to that type) requirements of this Standard are complied with.The deletion of Figures A1 to A12 is under consideration.

First published as AS 3131-1990.
Jointly revised and designated AS/NZS 3131:1995.

AS 3133-1989 Approval and test specification - Air break switches
AS 2420-1987 Fire test methods for solid insulating materials and non-metallic enclosures used in electrical equipment
AS/NZS 3122:1993 Approval and test specification - Socket-outlet adaptors
AS/NZS 3120:1999 Approval and test specification - Cord extension sockets
AS 3109.1-1987 Approval and test specification - Appliance couplers for household and similar general purposes - General requirements
AS/NZS 3112:1993 Approval and test specification - Plugs and socket-outlets
AS/NZS 3123:1994 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 3127-1987 Approval and test specification - Cord-line switches
AS 3100-1990 Approval and test specification - General requirements for electrical equipment
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)

AS 4509.1-1999 Stand-alone power systems Safety requirements
AS/NZS 3018:2001 Electrical installations - Domestic installations
AS/NZS 60598.1:2001 Luminaires General requirements and tests (IEC 60598.1:1996, MOD)
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.