This part of IEC 61097 specifies the minimum performance requirements, technical characteristics and type-testing requirements of the satellite emergency position-indicating radio beacon used in the COSPAS-SARSAT satellite system (satellite EPIRB), as required by Regulation IV/7.1.6 of the 1988 amendments to the 1974 International Convention for Safety of Life at Sea (SOLAS), and which is associated with IEC 60945 (General requirements). When a requirement in this standard is different from IEC 60945, the requirement in this standard shall take precedence.This standard also includes minimum performance standards for a manually activated satellite EPIRB without float-free release mechanism (see annex C).This standard incorporates the performance standards of IMO Resolutions A.763(18) A.810(19) Performance Standards for float-free satellite emergency position-indicating radio beacons operating on 406 MHz and A.662(16) Performance Standards for float-free release and activation arrangements for emergency radio equipment, the International Telecommunication Union (ITU) Radio Regulations as well as the technical characteristics for such transmitters contained in Recommendation ITU-R M.633-1 M.633-2 (as amended), and takes account of the general requirements contained in IMO Resolution A.694(17).All texts of this standard, whose wording is identical to that in the IMO SOLAS Convention 1974 as amended in 1988 and Resolutions A.658(16), A.662(16), A.689(17), A.694(17), A.696(17), A.702(17) and A.763(18) A 810(19) and Recommendation ITU-R M.633-1 M.633-2 (as amended) will be printed in italics and the Resolution/Recommendation and paragraph number indicated between brackets.NOTES1 Classes of satellite EPIRB's considered in this document are:- Class 1: Float-free (-40 C to +55C). The float-free release mechanism (A.662 (16)) shall be capable of operating throughout the temperature range of -40C to +65C.This class is not required by IMO Resolutions but (633.1, annex I) may be applied at the discretion of each Administration.- Class 2: Float-free (-20C to +55C). The float-free release mechanism (A.662 (16)) shall be capable of operating throughout the temperature range of -30C to +65C.2 Non-float-free, manually activated satellite EPIRB's in both classes are considered in annex C.3 All classes shall include a 121,5 MHz homing device, described in annex D.User experience of COSPAS-SARSAT EPIRB operation leading to some clarification of IMO performance standards is included in annex E.