AS/NZS 4509.1:2009
Current
The latest, up-to-date edition.
Stand-alone power systems Safety and installation (Reconfirmed 2017)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
21-12-2009
This Standard sets out safety and installation requirements for stand-alone power systems used for the supply of extra-low (ELV) and/or low voltage (LV) electric power to a single load, or an electrical installation in a single residence or building, or a group of residences or buildings and associated items with switchboards to AS/NZS 3000 requirements.
Committee |
EL-042
|
DocumentType |
Standard
|
ISBN |
0 7337 9343 6
|
Pages |
36
|
ProductNote |
Reconfirmed 20/01/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 20/01/2017
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out safety and installation requirements for stand-alone power systems used for the supply of extra-low (ELV) and/or low voltage (LV) electric power to a single load, or an electrical installation in a single residence or building, or a group of residences or buildings and associated items with switchboards to AS/NZS 3000 requirements.This Standard covers - (a) equipment up to, and including, the output of the stand-alone power system (i.e. the point of supply-see the definition in Clause 1.4.12); and(b) direct connection of a stand-alone power system to - (i) a single load (e.g. a water pump);(ii) a single electrical installation (e.g. a residence); or(iii) a group of independent electrical installations (e.g. a number of separate residences and/or buildings).This Standard includes minimum rating and over-current protection requirements for the consumers mains and earthing arrangements.NOTE: The connection from the output of the stand-alone power system to the electrical installation is regarded as the consumers mains (see AS/NZS 3000).This Standard, with additional safety requirements, shall be applied to systems with energy storage at LVSystem design considerations are detailed in AS 4509.2.NOTE: System maintenance matters are considered in Appendix A.
Originated in Australia as AS 4509.1-1999 and AS 4509.3-1990.
Jointly revised, amalgamated and designated as AS/NZS 4509.1:2009.
AS 1940-2004 | The storage and handling of flammable and combustible liquids |
AS 3011.1-1992 | Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells |
AS 1170.4-2007 | Structural design actions Earthquake actions in Australia (Reconfirmed 2018) |
AS 3011.2-1992 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3008.1.1:2009 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS 1170.4 SUPP 1-1993 | Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads - Commentary (Supplement to AS 1170.4-1993) |
AS/NZS 1170.2:2002 | Structural design actions Wind actions |
AS/NZS 3010:2005 | Electrical installations - Generating sets |
AS/NZS 3019:2007 | Electrical installations - Periodic verification |
AS 4509.2-2002 | Stand-alone power systems - System design guidelines |
AS 60038-2000 | Standard voltages |
AS/NZS 1768:2007 | Lightning protection |
AS/NZS 1125:2001 | Conductors in insulated electric cables and flexible cords (Reconfirmed 2017) |
AS/NZS 5033:2005 | Installation of photovoltaic (PV) arrays |
AS 4086.2-1997 | Secondary batteries for use with stand-alone power systems Installation and maintenance |
AS/NZS 4763(INT):2006 | Safety of Portable Inverters |
AS/NZS 3010:2017 | Electrical installations - Generating sets |
AS/NZS 5033:2012 | Installation and safety requirements for photovoltaic (PV) arrays |
AS/NZS 5139:2019 | Electrical installations - Safety of battery systems for use with power conversion equipment |
AS 4852.2:2019 | Variable message signs Portable signs |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 4509.2:2010 | Stand-alone power systems System design (Reconfirmed 2017) |