• Shopping Cart
    There are no items in your cart

AS/NZS 4805.2:2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Accessories for electric cables - Test requirements - Impregnated paper-insulated metal-sheathed cables for rated voltages from 1.9/3.3 (3.6) kV up to 19/33 (36) kV (excluding gas-pressure and oil-filled cables)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Superseded by

AS/NZS 4805.2:2007

Language(s)

English

Published date

01-01-2003

€57.40
Excluding VAT

1 - AS/NZS 4805.2:2003 ACCESSORIES FOR ELECTRIC CABLES-TEST REQUIREMENTS - IMPREGNATED PAPER-INSULATED METAL-SHEATHED CABLES...
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 REFERENCED DOCUMENTS
7 - 1.3 DEFINITIONS
7 - 1.3.1 Connector
7 - 1.3.2 Termination
7 - 1.3.3 Indoor termination
7 - 1.3.4 Outdoor termination
7 - 1.3.5 Terminal box
7 - 1.3.6 Straight joint
7 - 1.3.7 Branch joint
7 - 1.3.8 Transition joint
8 - 1.4 VOLTAGE DESIGNATIONS AND TEMPERATURE RATING
8 - 1.4.1 Rated voltages
8 - 1.4.2 Rated temperature
9 - SECTION 2 ASSEMBLY OF ACCESSORIES TO BE TESTED
9 - 2.1 CABLES
9 - 2.2 CONNECTORS
9 - 2.3 ACCESSORIES
9 - 2.4 ASSEMBLY INSTRUCTIONS
9 - 2.5 CONDITION OF ACCESSORIES
9 - 2.6 RECORDING
10 - SECTION 3 CONDITIONS AND RANGE OF APPROVAL
10 - 3.1 RANGE OF APPROVAL
10 - 3.2 CONDUCTOR MATERIAL
10 - 3.3 FORM OF CONDUCTOR
10 - 3.4 NUMBER OF CORES
10 - 3.5 TYPE OF CABLE
10 - 3.6 RATED VOLTAGE
11 - SECTION 4 TESTS
11 - 4.1 CATEGORY OF TESTS
11 - 4.2 TEST METHODS
11 - 4.3 TEST ARRANGMENTS
11 - 4.4 TEST SEQUENCES
11 - 4.5 TEST RESULTS
11 - 4.5.1 General
11 - 4.5.2 Accessory failure
12 - 4.5.3 Cable failure
18 - APPENDIX A - IDENTIFICATION OF THE TEST CABLE
18 - A1 PAPER INSULATED CABLES (see Clause 2.1)
19 - A2 EXTRUDED INSULATION CABLES (see Clause 2.1)
20 - APPENDIX B - TEST FOR 'HYDRAULICALLY BLOCKED' CONNECTORS USED IN TRANSITION JOINTS BETWEEN PAPER-IMPREGNATED CABLES AND...
20 - B1 TEST PROCEDURE
22 - APPENDIX C - HYDRAULIC PRESSURE TEST METHOD FOR CABLE TERMINATIONS
22 - C1 SCOPE
22 - C2 APPLICATION AND RANGE OF QUALIFICATION
22 - C3 PRINCIPLE
22 - C4 TEST SPECIMENS AND TEST CONFIGURATION
22 - C5 APPARATUS
23 - C6 HEATING / COOLING CYCLE
23 - C7 SET-UP AND TEST PROCEDURE
24 - C8 CRITERIA OF FAILURE
24 - C9 REPORTING OF RESULTS

Specifies the type test requirements on accessories for impregnated paper-insulated metal-sheathed cables with rated voltages up to 19/33 (36) kV, based on IEC 60055-1. Accessories covered are indoor and outdoor terminations, straight joints and branch joints, and transition joints connecting paper-insulated cables to cables with extruded insulation.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 5253 5
Pages
19
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies the requirements for type testing of accessories for impregnated paper-insulated metal-sheathed cables with rated voltages from 1.9/3.3 (3.6) kV up to 19/33 (36) kV, complying with AS 1026 or IEC 60055-1. The accessories covered by this Standard are (a) indoor and outdoor terminations of all designs, including those designed for installations in terminal boxes; (b) straight joints and branch joints of all designs, suitable for use underground or in air; and (c) transition joints connecting paper-insulated cables to cables with extruded insulation. Accessories for particular cables, such as submarine cables are not included. Approval to this Standard shall be obtained by carrying out the appropriate tests as set out in this Standard. These type tests shall apply only to new designs of accessories. By agreement with the purchaser, accessories which the manufacturer can demonstrate to have provided satisfactory service experience do not need to be type tested. It is not necessary to repeat these tests, once successfully completed, unless changes are made in the materials, design or manufacturing process which might affect the performance characteristics. Test methods are included in IEC 61442.

First published as AS/NZS 4805.2:2003.

AS 1026-1992 Electric cables - Impregnated paper insulated - Working voltages up to and including 33 kV

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.