1 - AS/NZS 4847.1(Int):2008 SELF-BALLASTED LAMPS FOR GENERAL LIGHTING SERVICES - TEST METHODS-ENERGY PERFORMANCE
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - 1 SCOPE
7 - 2 REFERENCED DOCUMENTS
8 - 3 DEFINITIONS
8 - 3.1 Beam angle (beam spread)
8 - 3.2 Efficacy
8 - 3.3 Final luminous flux
8 - 3.4 Initial values
8 - 3.5 Lamp failure
8 - 3.6 Lamp life
8 - 3.7 Lumen maintenance
8 - 3.8 Median lamp life
8 - 3.9 New lamp
8 - 3.10 Power factor
8 - 3.11 Rated values
8 - 3.12 Run-up time
9 - 3.13 Self-ballasted compact fluorescent lamp
9 - 3.14 Stabilization time
9 - 3.15 Starting time
9 - 3.16 Test voltage
9 - 3.17 Colour
9 - 3.18 Type
9 - 3.19 Type test
9 - 3.20 Type test sample
9 - 4 LAMP REQUIREMENTS
9 - 4.1 General conditions
9 - 4.2 Starting time
10 - 4.3 Run-up time
10 - 4.4 Low temperature starting
10 - 4.5 Lamp wattage
10 - 4.6 Power factor
10 - 4.7 Luminous flux and initial efficacy
10 - 4.8 Colour and colour rendering index
10 - 4.9 Switching withstand
10 - 4.10 Lamp life
10 - 4.11 Lumen maintenance
10 - 4.12 Light distribution ratio
10 - 4.13 Harmonics and EMC
10 - 4.14 Mercury content determination
10 - 4.15 Safety requirements
10 - 5 SAMPLING
12 - APPENDIX A - GENERAL CONDITIONS FOR MEASUREMENT OF PHOTOMETRIC AND ELECTRICAL CHARACTERISTICS
12 - A1 AIR MOVEMENT AND TEMPERATURE
12 - A1.1 Test room
12 - A1.2 Ageing room
12 - A2 SUPPLY
12 - A3 POSITION OF LAMP
12 - A4 LAMP STABILIZATION
13 - A5 LAMP AGEING
13 - A6 MEASUREMENT EQUIPMENT AND ACCURACY
13 - A6.1 Supply voltage for test
13 - A6.2 Supply voltage for ageing
13 - A7 ELECTRICAL MEASUREMENT
13 - A8 LUMINOUS FLUX MEASUREMENT
13 - A8.1 Measurement equipment for tests
13 - A8.2 Integrating sphere
14 - A8.3 Goniophotometer (distribution photometer)
14 - A8.4 Spectroradiometer
14 - A8.5 Colorimeter
14 - A9 TIME MEASUREMENT
15 - APPENDIX B - TEST FOR STARTING TIME
15 - B1 GENERAL
15 - B2 TEST CONDITIONS
16 - B3 TEST PROCEDURE
16 - B4 CALCULATIONS
18 - APPENDIX C - TEST FOR RUN-UP TIME
18 - C1 GENERAL
18 - C2 TEST CONDITIONS
18 - C3 PREPARATION OF APPARATUS
19 - C4 TEST PROCEDURE
19 - C5 CALCULATIONS
20 - APPENDIX D - MEASUREMENT OF INITIAL LUMINOUS FLUX, EFFICACY AND LUMEN MAINTENANCE
20 - D1 GENERAL
20 - D2 TEST CONDITIONS AND PREPARATION OF APPARATUS
20 - D2.1 All methods
20 - D2.2 Method A1 (Integrating sphere measurement: spectral photometry) andMethod A2 (Integrating sphere measurement: integrating method)
20 - D2.3 Method B (Goniophotometer: distribution photometer)
21 - D3 TEST PROCEDURE
21 - D3.1 All methods
21 - D3.2 Method A1 (Integrating sphere measurement: spectral photometry) and MethodA2 (Integrating sphere measurement: integrating method)
21 - D3.3 Method B (Goniophotometer: distribution photometer)
21 - D3.4 Calculations
23 - D4 INITIAL EFFICACY TEST
23 - D4.1 Test procedure
23 - D4.2 Calculations
23 - D5 LUMEN MAINTENANCE AND MAINTAINED EFFICACY TESTS
24 - APPENDIX E - TEST FOR LOW TEMPERATURE STARTING TIME
24 - E1 GENERAL
24 - E2 TEST CONDITIONS
24 - E3 TEST PROCEDURE
25 - APPENDIX F - TEST FOR SWITCHING WITHSTAND
26 - APPENDIX G - TEST FOR LAMP LIFE
27 - APPENDIX H - TEST FOR LIGHT DISTRIBUTION
28 - APPENDIX I - TEST REPORT
29 - APPENDIX J - BIBLIOGRAPHY