ASHRAE GUIDELINE 32 : 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
SUSTAINABLE, HIGH-PERFORMANCE OPERATIONS AND MAINTENANCE
Hardcopy , PDF
English
18-07-2018
25-03-2023
Foreword
1 Purpose
2 Scope
3 Definitions, Abbreviations, and Acronyms
4 Intended Users of the Guideline
5 Level 1: Senior Management Steps
6 Level II: Action Areas for Facility Managers
- Implementing the Change
7 Level III: Actions and Tools for Technicians
- Carrying Out Best Practices
8 References
9 Bibliography
Informative Annex A: Additional Resources
Informative Annex B: Benchmarking and Building Rating
Systems
Informative Annex C: Maintaining Indoor Air Quality (IAQ)
Informative Annex D: Measurement and Occupant Surveys for
Comfort and Indoor Environmental
Quality (IEQ)
Informative Annex E: Training Needs Assessment
Informative Annex F: Building Information Modeling (BIM)
Informative Annex G: Predictive Maintenance Techniques
Informative Annex H: Guidance for HVAC Energy Savings
Informative Annex I: Energy Performance Diagnostic Procedure
Informative Annex J: High-Performance Systems Sample Checklists
Pertains to the ongoing operational practices for a building and its systems, particularly with respect to energy efficiency, occupant comfort, indoor air quality (IAQ), health and safety.
| Committee |
TC 7.3
|
| DocumentType |
Standard
|
| Pages |
34
|
| PublisherName |
American Society of Heating, Refrigerating & Air Conditioning Engineers
|
| Status |
Superseded
|
| SupersededBy |
This guideline applies to the ongoing operational practices for a building and its systems, particularly with respect to energy efficiency, occupant comfort, indoor air quality (IAQ), health and safety.
| ASHRAE/ACCA 180 : 2008 | STANDARD PRACTICE FOR INSPECTION AND MAINTENANCE OF COMMERCIAL BUILDING HVAC SYSTEMS |
| ASHRAE HDBK REFRIGERATION : 2014 | ASHRAE HANDBOOK - REFRIGERATION |
| ASHRAE GUIDELINE 11 : 2009 | FIELD TESTING OF HVAC CONTROLS COMPONENTS |
| ASHRAE GUIDELINE 0 : 2013 | THE COMMISSIONING PROCESS |
| ASHRAE 52.2 : 2017 | METHOD OF TESTING GENERAL VENTILATION AIR-CLEANING DEVICES FOR REMOVAL EFFICIENCY BY PARTICLE SIZE |
| ASHRAE 189.1 : 2014 | DESIGN OF HIGH-PERFORMANCE GREEN BUILDINGS |
| AHRI 700 : 2015 | SPECIFICATIONS FOR REFRIGERANTS |
| ASHRAE 62.1 : 2016 | VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY |
| ASHRAE 100 : 2015 | ENERGY CONSERVATION IN EXISTING BUILDINGS |
| ASHRAE/ACCA 180 : 2008 | STANDARD PRACTICE FOR INSPECTION AND MAINTENANCE OF COMMERCIAL BUILDING HVAC SYSTEMS |
| ASHRAE 55 : 2017 | THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.