ASTM C 1015 : 2017 : REDLINE
Current
The latest, up-to-date edition.
Standard Practice for Installation of Cellulosic and Mineral Fiber Loose-Fill Thermal Insulation
English
15-03-2017
CONTAINED IN VOL. 04.06, 2017 Defines procedures for the installation of cellulosic and mineral fiber loose-fill insulation in ceilings, attics, and floor and wall cavities of new or existing housing and other framed buildings.
Committee |
C 16
|
DocumentType |
Redline
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1This practice covers procedures for the installation of cellulosic and mineral fiber loose-fill insulation in ceilings, attics, and floor and wall cavities of new or existing housing and other framed buildings.
1.2This practice applies only to the installation of dry loose-fill thermal insulation consisting of cellulosic materials or mineral fiber by pneumatic or pouring application.
1.3This practice covers the installation process from pre-installation inspection through post-installation procedure. It does not cover the production of the insulation materials.
1.4This practice is not intended to replace the manufacturer's installation instructions, but shall be used in conjunction with such instructions. This practice is not intended to supersede local, state, or federal codes.
1.5This practice assumes that the installer possesses a good working knowledge of the applicable codes and regulations, safety practices, tools, equipment, and methods necessary for the installation of thermal insulation materials. It also assumes that the installer understands the fundamentals of residential construction that affect the installation of insulation.
1.6The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 5.
NFPA 31 : 2016 | INSTALLATION OF OIL-BURNING EQUIPMENT |
CFR 16(PTS0-999) : 0 | COMMERCIAL PRACTICES |
ASTM C 764 : 2017 : REDLINE | Standard Specification for Mineral Fiber Loose-Fill Thermal Insulation |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
ICC 2003 INTERNATIONAL RESI. CODE : 2003 | INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO-FAMILY DWELLINGS |
ASTM C 739 : 2017 : REDLINE | Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
NFPA 211 : 2016 | CHIMNEYS, FIREPLACES, VENTS, AND SOLID FUEL-BURNING APPLIANCES |
ASTM C 168 : 2017-06 | TERMINOLOGY RELATING TO THERMAL INSULATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.