• ASTM C 1090/C1090M : 2015 : REDLINE

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Test Method for Measuring Changes in Height of Cylindrical Specimens of Hydraulic-Cement Grout

    Available format(s):  PDF

    Superseded date:  24-07-2023

    Language(s):  English

    Published date:  18-03-2016

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 04.02, 2016 Defines measurement of the changes in height of hydraulic-cement grout by the use of 75 by 150-mm [3 by 6-in.] cylinders, when the cylinders are protected so that the tendency to change in height does not include evaporation so as to cause drying, uptake of moisture, carbonation, or exposure to temperatures outside the range 23 +/- 2.0 degrees C [73 +/- 3.5 degrees F] or, optionally, to another specified temperature controlled within +/- 2.0 degrees C [+/- 3.5 degrees F].

    Scope - (Show below) - (Hide below)

    1.1This test method covers measurement of the changes in height of hydraulic-cement grout by the use of 75 by 150-mm [3 by 6-in.] cylinders, when the cylinders are protected so that the tendency to change in height does not include evaporation so as to cause drying, uptake of moisture, carbonation, or exposure to temperatures outside the range 23 ± 2.0°C [73 ± 3.5°F] or, optionally, to another specified temperature controlled within ±2.0°C [±3.5°F].

    1.2If desired, this test method can be adapted to studies of changes in height involving either schedules or environmental treatment different from the standard procedures prescribed by this test method.

    1.3The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Some values have only SI units because the inch-pound equivalents are not used in practice..

    Note 1:Sieve size is identified by its standard designation in Specification E11. The alternative designation given in parentheses is for information only and does not represent a different standard sieve size.

    1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee C 09
    Development Note Supersedes ASTM C 1090. (03/2016)
    Document Type Redline
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    ASTM C 1107/C1107M : 2017 : REDLINE Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM C 305 : 2014 : REDLINE Standard Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency
    ASTM C 827/C827M : 2016 : REDLINE Standard Test Method for Change in Height at Early Ages of Cylindrical Specimens of Cementitious Mixtures
    ASTM C 172/C172M : 2017 : REDLINE Standard Practice for Sampling Freshly Mixed Concrete
    ASTM E 11 : 2017 : REDLINE Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves
    ASTM C 670 : 2015 : REDLINE Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective