• Shopping Cart
    There are no items in your cart

ASTM C 335/C335M : 2017 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Steady-State Heat Transfer Properties of Pipe Insulation

Available format(s)

PDF

Superseded date

20-04-2023

Language(s)

English

Published date

24-10-2017

€74.48
Excluding VAT

CONTAINED IN VOL. 04.06, 2017 Specifies the measurement of the steady-state heat transfer properties of pipe insulations.

Committee
C 16
DevelopmentNote
Supersedes ASTM C 335. (10/2010)
DocumentType
Redline
Pages
14
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This test method covers the measurement of the steady-state heat transfer properties of pipe insulations. Specimen types include rigid, flexible, and loose fill; homogeneous and nonhomogeneous; isotropic and nonisotropic; circular or non-circular cross section. Measurement of metallic reflective insulation and mass insulations with metal jackets or other elements of high axial conductance is included; however, additional precautions must be taken and specified special procedures must be followed.

1.2The test apparatus for this purpose is a guarded-end or calibrated-end pipe apparatus. The guarded-end apparatus is a primary (or absolute) method. The guarded-end method is comparable, but not identical to ISO 8497.

1.3The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.4When appropriate, or as required by specifications or other test methods, the following thermal transfer properties for the specimen can be calculated from the measured data (see 3.2):

1.4.1The pipe insulation lineal thermal resistance and conductance,

1.4.2The pipe insulation lineal thermal transference,

1.4.3The surface areal resistance and heat transfer coefficient,

1.4.4The thermal resistivity and conductivity,

1.4.5The areal thermal resistance and conductance, and

1.4.6The areal thermal transference.

Note 1:In this test method the preferred resistance, conductance, and transference are the lineal values computed for a unit length of pipe. These must not be confused with the corresponding areal properties computed on a unit area basis which are more applicable to flat slab geometry. If these areal properties are computed, the area used in their computation must be reported.

Note 2:Discussions of the appropriateness of these properties to particular specimens or materials may be found in Test Method C177, Test Method C518, and in the literature (1).2

1.5This test method allows for operation over a wide range of temperatures. The upper and lower limit of the pipe surface temperature is determined by the maximum and minimum service temperature of the specimen or of the materials used in constructing the apparatus. In any case, the apparatus must be operated such that the temperature difference between the exposed surface and the ambient is sufficiently large enough to provide the precision of measurement desired. Normally the apparatus is operated in closely controlled still air ambient from 15 to 30°C, but other temperatures, other gases, and other velocities are acceptable. It is also acceptable to control the outer specimen surface temperature by the use of a heated or cooled outer sheath or blanket or by the use of an additional uniform layer of insulation.

1.6The use any size or shape of test pipe is allowable provided that it matches the specimens to be tested. Normally the test method is used with circular pipes; however, its use is permitted with pipes or ducts of noncircular cross section (square, rectangular, hexagonal, etc.). One common size used for interlaboratory comparison is a pipe with a circular cross section of 88.9-mm diameter (standard nominal 80-mm [3-in.] pipe size), although several other sizes are reported in the literature (2-4).

1.7The test method applies only to test pipes with a horizontal or vertical axis. For the horizontal axis, the literature includes using the guarded-end, the calibrated, and the calibrated-end cap methods. For the vertical axis, no experience has been found to support the use of the calibrated or calibrated-end methods. Therefore the method is restricted to using the guarded-end pipe apparatus for vertical axis measurements.

1.8This test method covers two distinctly different types of pipe apparatus, the guarded-end and the calibrated or calculated-end types, which differ in the treatment of axial heat transfer at the end of the test section.

(A)Units are given in terms of (1) the absolute joule per second or watt, (2) the calorie (International Table) = 4.1868 J, or the British thermal unit (International Table) = 1055.06 J.
(B)This is the SI (International System of Units) unit.

1.8.1The guarded-end apparatus utilizes separately heated guard sections at each end, which are controlled at the same temperature as the test section to limit axial heat transfer. This type of apparatus is preferred for all types of specimens within the scope of this test method and must be used for specimens incorporating elements of high axial conductance.

1.8.2The calibrated or calculated-end apparatus utilizes insulated end caps at each end of the test section to minimize axial heat transfer. Corrections based either on the calibration of the end caps under the conditions of test or on calculations using known material properties, are applied to the measured test section heat transfer. These apparatuses are not applicable for tests on specimens with elements of high axial conductance such as reflective insulations or metallic jackets. There is no known experience on using these apparatuses for measurements using a vertical axis.

1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

MIL-DTL-32585 Base Document:2017 Insulation, Thermal and Acoustic, Fibrous Glass
ASTM C 1058/C1058M : 2010 Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation
ASTM C 447 : 2015 : REDLINE Standard Practice for Estimating the Maximum Use Temperature of Thermal Insulations
ASTM C 1058/C1058M : 2010 : R2015 Standard Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation
ASTM C 547 : 2017 : REDLINE Standard Specification for Mineral Fiber Pipe Insulation
ASTM C 1696 : 2016 : REDLINE Standard Guide for Industrial Thermal Insulation Systems
ASTM C 610 : 2017 : REDLINE Standard Specification for Molded Expanded Perlite Block and Pipe Thermal Insulation
NBR 11363 : 2014 PIPE THERMAL INSULATION BASED OF ROCK (STONE) WOOL

ASTM E 230 : 2003 Standard Specification and Temperature-Electromotive Force (EMF) Tables for Standardized Thermocouples
ASTM C 518 : 2017 : REDLINE Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
ASTM C 680 : 2014 : REDLINE Standard Practice for Estimate of the Heat Gain or Loss and the Surface Temperatures of Insulated Flat, Cylindrical, and Spherical Systems by Use of Computer Programs
ISO 8497:1994 Thermal insulation — Determination of steady-state thermal transmission properties of thermal insulation for circular pipes
ASTM C 168 : 2017-06 TERMINOLOGY RELATING TO THERMAL INSULATION