ASTM C 739 : 2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation
Hardcopy , PDF
26-05-2021
English
02-08-2017
Committee |
C 16
|
DocumentType |
Standard
|
Pages |
11
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This specification covers the composition and physical requirements of chemically treated, recycled cellulosic fiber loose-fill type thermal insulation for use in attics or enclosed spaces in housing, and other framed buildings within the ambient temperature range from −45 to 90°C by pneumatic or pouring application. While products that comply with this specification are used in various constructions, they are adaptable primarily, but not exclusively, to wood joist, rafters, and stud construction.
1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.4This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM C 1630 : 2019 | Standard Guide for Development of Coverage Charts for Loose-Fill Thermal Building Insulations |
ASTM C 1015 : 2017 | Standard Practice for Installation of Cellulosic and Mineral Fiber Loose-Fill Thermal Insulation |
ASTM C 1558 : 2019 | Standard Guide for Development of Standard Data Records for Computerization of Thermal Transmission Test Data for Thermal Insulation |
ASTM E 970 : 2017 | Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source |
ASTM C 1373/C1373M : 2011 : R2017 | Standard Practice for Determination of Thermal Resistance of Attic Insulation Systems Under Simulated Winter Conditions |
ASTM C 1617 : 2019 | Standard Practice for Quantitative Accelerated Laboratory Evaluation of Extraction Solutions Containing Ions Leached from Thermal Insulation on Aqueous Corrosion of Metals |
ASTM C 687 : 2018 | Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation |
ASTM C 1497 : 2016 | Standard Specification for Cellulosic Fiber Stabilized Thermal Insulation |
ASTM C 1374 : 2014 | Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation |
ASTM C 1114 : 2006 : R2013 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM C 1114 : 2006 : R2019 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM E 177 : 1990 : REV A : R1996 | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM C 1485 : 2013 | Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source |
ASTM C 1485 : 2000 | Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source |
ASTM C 1363 : 2019 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 1338 : 2000 | Standard Test Method for Determining Fungi Resistance of Insulation Materials and Facings |
ASTM C 1363 : 2005 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 1363 : 1997 | Standard Test Method for the Thermal Performance of Building Assemblies by Means of a Hot Box Apparatus |
ASTM C 1374 : 2003 | Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation |
ASTM E 691 : 2020 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM C 1114 : 2006 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM C 1338 : 2014 | Standard Test Method for Determining Fungi Resistance of Insulation Materials and Facings |
ASTM C 518 : 2002 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM E 691 : 2019 : EDT 1 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM C 1338 : 2019 | Standard Test Method for Determining Fungi Resistance of Insulation Materials and Facings |
ASTM C 1374 : 1997 | Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation |
ASTM C 1338 : 2008 | Standard Test Method for Determining Fungi Resistance of Insulation Materials and Facings |
ASTM C 1114 : 2000 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM E 691 : 2009 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM C 1363 : 2011 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ASTM C 1374 : 2018 | Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation |
ASTM C 1114 : 2000 : R2006 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus |
ASTM C 1485 : 2006 | Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source |
ASTM C 1485 : 2019 | Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source |
ASTM C 1374 : 2003 : R2009 | Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation |
ASTM C 518 : 1998 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.