ASTM D 1676 : 2017 : REDLINE
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Methods for Film-Insulated Magnet Wire
23-09-2024
English
01-11-2017
CONTAINED IN VOL. 10.01, 2017 Specifies procedures for testing film-insulated magnet wire that is used in electrical apparatus.
Committee |
D 09
|
DocumentType |
Redline
|
Pages |
36
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1These test methods cover procedures for testing film-insulated magnet wire that is used in electrical apparatus. These test methods are intended primarily for the evaluation of the electrical insulating materials used. The intent is that these test methods be used, except where modified, by individual specifications for particular applications.
1.2These test methods present different procedures for evaluating given properties of round, rectangular or square, copper or aluminum film-insulated magnet wire.
1.3The values stated in inch-pound units are the standard. The SI units in parentheses are provided for information only.
1.4The test methods appear in the following sections:
Sections | |
Bond Strength | 4 – 12 |
Burnout (AC Overload Resistance) | 13 – 21 |
Chemical Resistance | 22 – 28 |
Coefficient of Friction | 29 – 37 |
Continuity, DC High Voltage | 38 – 45 |
Continuity, DC Low Voltage | 46 – 53 |
Completeness of Cure | 54 – 60 |
Cut-Through Temperature (Thermoplastic Flow) | 61 – 68 |
Dielectric Breakdown AC Voltage | 69 – 75 |
Dielectric Breakdown AC Voltage after Bending | 76 – 82 |
Dielectric Breakdown AC Voltage at Elevated Temperatures | 83 – 89 |
Dielectric Breakdown AC Voltage after Conditioning in Refrigerant Atmosphere | 90 – 99 |
Dimensional Measurement | 100 – 106 |
Dissipation Factor Measurement | 107 – 114 |
Electrical Resistance | 115 – 121 |
Elongation | 122 – 129 |
Extractables, Refrigerant | 130 – 140 |
Film Adherence and Flexibility | 141 – 148 |
Formability: | |
a) Elastic Ratio | 152 |
b) Low Stress Elongation | 153 |
c) Spring Back | 154-155 |
Heat Shock | 156 – 162 |
Oiliness | 163 – 169 |
Scrape Resistance, Unidirectional | 170 – 177 |
Solderability | 178 – 185 |
Resistance to Insulating Liquids and Hydrolytic Stability | 186 – 195 |
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in 9.5, 19.1, 19.3, 19.8, 52.1, 58, 59.1, 74.1, 112.1, 135.4, and 182.3.
Note 1:This test method is related to IEC 60851. Since both methods contain multiple test procedures, many procedures are technically equivalent while others differ significantly.
1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D 1711 : 2015 : REDLINE | Standard Terminology Relating to Electrical Insulation |
ASTM B 279 : 2013 | Standard Test Method for Stiffness of Bare Soft Square and Rectangular Copper and Aluminum Wire for Magnet Wire Fabrication |
ASTM D 374/D374M : 2016 | Standard Test Methods for Thickness of Solid Electrical Insulation |
ASTM D 1533 : 2012 : REDLINE | Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration |
ASTM E 220 : 2013 : REDLINE | Standard Test Method for Calibration of Thermocouples By Comparison Techniques |
ASTM B 43 : 2015 : REDLINE | Standard Specification for Seamless Red Brass Pipe, Standard Sizes |
ASTM E 8 : 2004 | Standard Test Methods for Tension Testing of Metallic Materials |
ASTM B 193 : 2016 : REDLINE | Standard Test Method for Resistivity of Electrical Conductor Materials |
ASTM D 5423 : 2014 | Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.