ASTM D 5712 : 2015 : REDLINE
Current
The latest, up-to-date edition.
Standard Test Method for Analysis of Aqueous Extractable Protein in Latex, Natural Rubber, and Elastomeric Products Using the Modified Lowry Method
English
01-07-2015
CONTAINED IN VOL. 09.02, 2015 Gives an analytical test for determination of the amount of total aqueous extractable protein associated with natural rubber (NR) and rubber products.
Committee |
D 11
|
DocumentType |
Redline
|
Pages |
12
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1This test method covers an analytical test for determining the amount of total aqueous extractable protein associated with NR, latex, and elastomeric products. Water soluble proteins are extracted in a buffer solution and then precipitated to concentrate them and also to separate them from water soluble substances that may interfere with the determination. The extracted protein is redissolved and quantified colorimetrically by the modified Lowry method using a protein standard.
1.2For the purpose of this test method, the range of protein measurement will be based on the limit of detection and quantitation and recorded in micrograms per dm2 test specimen.
1.3The test method is designed to be accurate and compatible with the industrial environment.
1.4Steps are included in this test method to minimize the effects of interfering substances.
1.5It is recognized that other methods for the analysis of leachable proteins exist and these may be used for routine quality control purposes provided they have been validated and a correlation established against the reference method specified by this test method.
1.6This test method has not been validated for use with lubricated products such as condoms. Condoms with different lubricants as typically marketed, have not been tested in an ASTM ILS to determine if, and if so to what degree, the lubricant interferes with the assay.
1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 7329 : 2007 : R2012 | Standard Specification for Food Preparation and Food Handling (Food Service) Gloves |
ASTM D 3578 : 2005 : R2010 | Standard Specification for Rubber Examination Gloves |
ASTM D 3577 : 2009 : EDT 1 | Standard Specification for Rubber Surgical Gloves |
ASTM D 7850 : 2013 | Standard Specification for Biological Properties of Industry Reference Materials (IRM) |
ASTM D 7198 : 2005 | Standard Specification for Disposable Embalming Gloves for Single-Use Applications |
ASTM D 7103 : 2006 : R2013 | Standard Guide for Assessment of Medical Gloves |
BS EN 455-3:2015 | Medical gloves for single use Requirements and testing for biological evaluation |
16/30346829 DC : 0 | BS ISO 16038 - MALE CONDOMS - GUIDANCE ON THE USE OF ISO 4074 AND ISO 23409 IN THE QUALITY MANAGEMENT CONDOMS |
ASTM D 7103 : 2006 : EDT 1 | Standard Guide for Assessment of Medical Gloves |
13/30281504 DC : 0 | BS EN 455-3 - MEDICAL GLOVES FOR SINGLE USE - PART 3: REQUIREMENTS AND TESTING FOR BIOLOGICAL EVALUATION |
ASTM D 3577 : 2009 : R2015 | Standard Specification for Rubber Surgical Gloves |
ASTM D 3578 : 2005 | Standard Specification for Rubber Examination Gloves |
ASTM D 7198 : 2005 : R2012 | Standard Specification for Disposable Embalming Gloves for Single-Use Applications |
ASTM D 345 : 2002 | Side bearings of the freight wagon bogies. General specifications |
NFPA 1999 : 2018 | PROTECTIVE CLOTHING AND ENSEMBLES FOR EMERGENCY MEDICAL OPERATIONS |
ASTM D 7103 : 2006 | Standard Guide for Assessment of Medical Gloves |
ASTM D 7427 : 2016 : REDLINE | Standard Test Method for Immunological Measurement of Four Principal Allergenic Proteins (Hev b 1, 3, 5 and 6.02) in Hevea Natural Rubber and Its Products Derived from Latex |
ASTM D 3577 : 2009 | Standard Specification for Rubber Surgical Gloves |
ASTM D 1076 : 2015 : REDLINE | Standard Specification for Rubber—Concentrated, Ammonia Preserved, Creamed, and Centrifuged Natural Latex |
ISEA 105 : 2016 | HAND PROTECTION CLASSIFICATION |
ISO 16038:2017 | Male condoms — Guidance on the use of ISO 4074 and ISO 23409 in the quality management of condoms |
PREN 455-3 : DRAFT 2013 | MEDICAL GLOVES FOR SINGLE USE - PART 3: REQUIREMENTS AND TESTING FOR BIOLOGICAL EVALUATION |
BS ISO 16038:2017 | Male condoms. Guidance on the use of ISO 4074 and ISO 23409 in the quality management of condoms |
ASTM D 3578 : 2005 : R2015 | Standard Specification for Rubber Examination Gloves |
UNE-EN 455-3:2015 | Medical gloves for single use - Part 3: Requirements and testing for biological evaluation |
I.S. EN 455-3:2015 | MEDICAL GLOVES FOR SINGLE USE - PART 3: REQUIREMENTS AND TESTING FOR BIOLOGICAL EVALUATION |
EN 455-3:2015 | Medical gloves for single use - Part 3: Requirements and testing for biological evaluation |
NSF P155-1-08 : 2003 | NSF-DISPOSABLE FOOD CONTACT GLOVES |
04/30050436 DC : DRAFT JUN 2004 | BS ISO 22613 - PROTECTIVE CLOTHING - GENERAL TEST METHODS AND PERFORMANCE REQUIREMENTS FOR HAND PROTECTION |
ASTM D 7329 : 2007 | Standard Specification for Food Preparation and Food Handling (Food Service) Gloves |
ASTM D 7329 : 2007 : R2018 | Standard Specification for Food Preparation and Food Handling (Food Service) Gloves |
ASTM D 3578 : 2005 : EDT 1 | Standard Specification for Rubber Examination Gloves |
ASTM D 4483 : 2014-02 | PRACTICE FOR EVALUATING PRECISION FOR TEST METHOD STANDARDS IN THE RUBBER AND CARBON BLACK MANUFACTURING INDUSTRIES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.