ASTM D 6007 : 2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber
Hardcopy , PDF
05-09-2022
English
18-12-2014
This test method measures the formaldehyde concentrations in air emitted by wood product test specimens under defined test conditions of temperature and relative humidity.
Committee |
D 07
|
DocumentType |
Test Method
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method measures the formaldehyde concentrations in air emitted by wood product test specimens under defined test conditions of temperature and relative humidity. Results obtained from this small-scale chamber test method are intended to be comparable to results obtained from testing larger product samples by the large chamber test method for wood products, ASTM Test Method E1333. The results may be correlated to values obtained from ASTM Test Method E1333. The quantity of formaldehyde in an air sample from the small chamber is determined by a modification of NIOSH 3500 chromotropic acid test procedure. As with ASTM Test Method E1333, other analytical procedures may be used to determine the quantity of formaldehyde in the air sample provided that such methods give results comparable to those obtained by using the chromotropic acid procedure. However, the test results and test report must be properly qualified and the analytical procedure employed must be accurately described.
1.2The wood-based panel products to be tested by this test method are characteristically used for different applications and are tested at different relative amounts or loading ratios to reflect different applications. This is a test method that specifies testing at various loading ratios for different product types. However, the test results and test report must be properly qualified and must specify the make-up air flow, sample surface area, and chamber volume.
1.3Ideal candidates for small-scale chamber testing are products relatively homogeneous in their formaldehyde release characteristics. Still, product inhomogeneities must be considered when selecting and preparing samples for small-scale chamber testing.
1.4The values stated in SI units are the standard values. Any values given in parentheses are for information only.
1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM D 7911 : 2019 | Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test |
ASTM D 8407 : 2021 | Standard Guide for Measurement Techniques for Formaldehyde in Air |
ASTM D 6330 : 2020 | Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions |
ASTM D 8345 : 2021 | Standard Test Method for Determination of an Emission Parameter for Phthalate Esters and Other Non-Phthalate Plasticizers from Planar Polyvinyl Chloride Indoor Materials for Use in Mass Transfer Modeling Calculations |
ASTM D 5116 : 2017 | Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products |
ASTM D 7911 : 2014 | Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test |
ASTM D 7706 : 2017 | Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers |
ASTM D 8141 : 2017 | Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments |
ASTM D 6330 : 1998 : R2014 | Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions |
ASTM D 3195 : 1990 : R2004 | Standard Practice for Rotameter Calibration |
ASTM E 1333 : 2010 | Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber |
ASTM E 220 : 2019 | Standard Test Method for Calibration of Thermocouples By Comparison Techniques |
ASTM E 1333 : 2014 | Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber |
ASTM E 691 : 2020 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 691 : 2019 : EDT 1 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM E 1333 : 1996 | Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber |
ASTM E 77 : 2014 : EDT 1 | Standard Test Method for Inspection and Verification of Thermometers |
ASTM E 691 : 2022 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM D 5197 : 1997 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM E 691 : 2009 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM D 5221 : 1992 | Standard Test Method for Continuous Measurement of Formaldehyde in Air (Withdrawn 1997) |
ASTM E 691 : 2021 | Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method |
ASTM D 5197 : 2016 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 5197 : 2009 : EDT 1 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 5197 : 2021 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM E 77 : 1998 | Standard Test Method for Inspection and Verification of Thermometers |
ASTM D 5197 : 2003 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM D 5197 : 2009 | Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology) |
ASTM E 77 : 2014 : R2021 | Standard Test Method for Inspection and Verification of Thermometers |
ASTM D 3195 : 1990 : R1998 : EDT 1 | Standard Practice for Rotameter Calibration |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.