• ASTM D 6113 : 2016 : REDLINE

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables

    Available format(s):  PDF

    Superseded date:  17-05-2021

    Language(s):  English

    Published date:  01-11-2016

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 10.02, 2017 Gives several fire-test-response characteristics, including the time to sustained flaming, heat release rate, total heat released, effective heat of combustion, and specific extinction area; are measured or calculated by this test method at a constant radiant heating flux.

    Scope - (Show below) - (Hide below)

    1.1This is a fire-test-response standard.

    1.2Several fire-test-response characteristics, including the time to sustained flaming, heat release rate, total heat released, effective heat of combustion, and specific extinction area; are measured or calculated by this test method at a constant radiant heating flux. For specific limitations see also 5.7 and Section 6.

    1.3The tests are conducted by burning the electrical insulating materials contained in electrical or optical fiber cables when the cable test specimens, excluding accessories, are subjected to radiant heat.

    1.4The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

    1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability or regulatory limitations prior to use. For specific precautionary statements, see Section 7.

    1.6This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.

    1.7Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

    General Product Information - (Show below) - (Hide below)

    Committee D 09
    Document Type Redline
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    ASTM D 5485 : 2016 : REDLINE Standard Test Method for Determining the Corrosive Effect of Combustion Products Using the Cone Corrosimeter
    NFPA 556 : 2016 GUIDE ON METHODS FOR EVALUATING FIRE HAZARD TO OCCUPANTS OF PASSENGER ROAD VEHICLES
    NFPA 555 : 2017 METHODS FOR EVALUATING POTENTIAL FOR ROOM FLASHOVER
    NFPA 556 : 2020 GUIDE ON METHODS FOR EVALUATING FIRE HAZARD TO OCCUPANTS OF PASSENGER ROAD VEHICLES
    UNE-EN 60695-8-2:2017 Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods
    EN 60695-8-2:2017 Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods
    ASTM E 2102 : 2017 : REDLINE Standard Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant Heater
    I.S. EN 60695-8-2:2017 FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS
    ASTM E 2067 : 2015 : REDLINE Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests
    BS IEC/TS 60695-8-2:2001 Fire hazard testing. Heat release Summary and relevance of test methods
    BS EN 60695-8-2:2017 Fire hazard testing Heat release. Summary and relevance of test methods
    IEC TR 60695-8-2:2008 Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods
    13/30277762 DC : 0 BS EN 60695-8-2 IEC 60695-8-2 ED 1.0 - FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS
    PD IEC/TR 60695-8-2:2008 Fire hazard testing Heat release. Summary and relevance of test methods

    Standards Referencing This Book - (Show below) - (Hide below)

    UL 1685:4ED 2015-07 Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables
    NFPA 262 : 2015 METHOD OF TEST FOR FLAME TRAVEL AND SMOKE OF WIRES AND CABLES FOR USE IN AIR-HANDLING SPACES
    IEEE 1202-2006 IEEE Standard for Flame-Propagation Testing of Wire & Cable
    ASTM D 618 : 2013 : REDLINE Standard Practice for Conditioning Plastics for Testing
    NFPA 287 : 2017 STANDARD TEST METHODS FOR MEASUREMENT OF FLAMMABILITY OF MATERIALS IN CLEANROOMS USING A FIRE PROPAGATION APPARATUS (FPA)
    IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
    IEC TS 60695-5-2:2002 Fire hazard testing - Part 5-2: Corrosion damage effects of fire effluent - Summary and relevance of test methods
    ASTM D 1711 : 2015 : REDLINE Standard Terminology Relating to Electrical Insulation
    ISO 13943:2017 Fire safety — Vocabulary
    ASTM E 906 : 2009 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method
    ASTM E 2965 : 2017 : REDLINE Standard Test Method for Determination of Low Levels of Heat Release Rate for Materials and Products Using an Oxygen Consumption Calorimeter
    UL 1666:5ED 2007-02 Test for Flame Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts
    ASTM E 1474 : 2014 : REDLINE Standard Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter
    ISO 11907-4:1998 Plastics — Smoke generation — Determination of the corrosivity of fire effluents — Part 4: Dynamic decomposition method using a conical radiant heater
    ASTM E 1354 : 2017 : REDLINE Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
    ASTM D 5485 : 2016 : REDLINE Standard Test Method for Determining the Corrosive Effect of Combustion Products Using the Cone Corrosimeter
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective