ASTM D 876 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Methods for Nonrigid Vinyl Chloride Polymer Tubing Used for Electrical Insulation
Hardcopy , PDF
15-02-2021
English
10-12-2013
These test methods cover the testing of general-purpose (Grade A), low-temperature (Grade B), and high-temperature (Grade C)2 nonrigid vinyl chloride polymer tubing, or its copolymers with other materials, for use as electrical insulation.
Committee |
D 09
|
DocumentType |
Test Method
|
Pages |
13
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1These test methods cover the testing of general-purpose (Grade A), low-temperature (Grade B), and high-temperature (Grade C)2 nonrigid vinyl chloride polymer tubing, or its copolymers with other materials, for use as electrical insulation. For the purpose of these test methods nonrigid tubing shall be tubing having an initial elongation in excess of 100 % at break.
1.2The values stated in inch-pound units are to be regarded as standard, except for temperature, which shall be expressed in degrees Celsius. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3The procedures appear in the following sections:
| | ASTM Reference Standard |
Brittleness Temperature | 43 – 45 | D746 |
Corrosion Tests | 74 – 85 | D1000 |
Dielectric Breakdown Voltage at High Humidity | 65 – 73 | E104 |
Dielectric Breakdown Voltage | 58 – 64 | D149 |
Dimensional Tests | 8 – 14 | D374 |
Effect of Elevated Temperatures | 25 – 36 | D412 |
Flammability Test | 15 – 21 | |
Oil Resistance Test | 35 – 42 | D471 |
Penetration Test | 46 – 51 | |
Sampling | 6 | |
Strain Relief Test | 68 – 73 | |
Tension Test | 22 – 24 | D412 |
Test Conditions | 7 | |
Volume Resistivity | 52 – 57 | D257 |
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 5.
1.5For fire test caveats, see Section 15.
ASTM D 8355 : 2020 | Standard Test Methods for Flammability of Electrical Insulating Materials Used for Sleeving or Tubing |
ASTM D 5025 : 2020 : REV A | Standard Specification for Laboratory Burner Used for Small-Scale Burning Tests on Plastic Materials |
ASTM D 3006 : 2010 : R2017 | Standard Specification for Polyethylene Plastic Pressure-Sensitive Electrical Insulating Tape (Withdrawn 2022) |
ASTM D 1675 : 2018 | Standard Test Methods for Polytetrafluoroethylene Tubing |
ASTM D 922 : 2018 | Standard Specification for Nonrigid Vinyl Chloride Polymer Tubing |
ASTM D 2671 : 2013 | Standard Test Methods for Heat-Shrinkable Tubing for Electrical Use |
ASTM D 1000 : 2017 | Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications |
ASTM D 1711 : 2002 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2011 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2011 : REV A | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2013 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1000 : 2004 : EDT 1 | Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications |
ASTM D 1000 : 2010 | Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications |
ASTM D 1711 : 1999 | Standard Terminology Relating to Electrical Insulation |
ASTM D 5032 : 2011 | Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions |
ASTM D 1711 : 2014 : REV A | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2015 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2014 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1000 : 2009 | Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications |
ASTM D 5032 : 2019 | Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions |
ASTM D 1711 : 2020 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1711 : 2008 | Standard Terminology Relating to Electrical Insulation |
ASTM D 1000 : 1999 | Standard Test Method for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications |
ASTM D 1000 : 2004 | Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications |
ASTM D 5032 : 1997 | Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.