ASTM E 1233 : 2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential
English
01-04-2006
11-11-2014
ASTM E 1233/E1233M : 2014
ASTM E 1233/E1233M : 2014 : REDLINE
CONTAINED IN VOL. 04.11, 2014 Specifies the structural performance of exterior windows, doors, skylights, and curtain walls under cyclic air pressure differential, using a test chamber.
| Committee |
E 06
|
| DocumentType |
Test Method
|
| Pages |
10
|
| PublisherName |
American Society for Testing and Materials
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
1.1 This test method describes the determination of the structural performance of exterior windows, doors, skylights, and curtain walls under cyclic air pressure differential, using a test chamber. This test method is applicable to all curtain wall assemblies, including, but not limited to, metal, glass, masonry, and stone components.
1.2 This test method is intended only for evaluating the structural performance associated with the specified test specimen, and not the structural performance of adjacent construction.
1.3 Procedure A shall be used for life cycle test loads.
1.4 Procedure B shall be used for wind event test loads.
1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section .
The text of this test method references notes and footnotes that provide explanatory materials. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
| FM 4350 : 2006 | WINDSTORM RESISTANT FENESTRATIONS |
| ASTM E 1886 : 2013 : REV A | Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials |
| ASTM E 330 : 2002 : R2010 | Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference |
| ASTM E 2570 : 2007 | Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage |
| ASTM E 2136 : 2004 | Standard Guide for Specifying and Evaluating Performance of Single Family Attached and Detached Dwellings-Durability |
| ASTM E 2136 : 2004 : R2013 | Standard Guide for Specifying and Evaluating Performance of Single Family Attached and Detached Dwellings—Durability (Withdrawn 2022) |
| ASTM E 330 : 2002 | Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference |
| ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
| ASTM E 1996 : 2017 : REDLINE | Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes |
| ASTM E 998 : 2012 : REDLINE | Standard Test Method for Structural Performance of Glass in Windows, Curtain Walls, and Doors Under the Influence of Uniform Static Loads by Nondestructive Method |
| ASTM E 1300 : 2016 : REDLINE | Standard Practice for Determining Load Resistance of Glass in Buildings |
| ANSI A58.1 : 1982 | DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, MINIMUM, |
| ASTM E 997 : 2015 : REDLINE | Standard Test Method for Evaluating Glass Breakage Probability Under the Influence of Uniform Static Loads by Proof Load Testing |