ASTM E 1249 : 2015 : REDLINE
Current
The latest, up-to-date edition.
Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources
English
01-06-2015
CONTAINED IN VOL. 12.02, 2015 Specifies recommended procedures for the use of dosimeters, such as thermoluminescent dosimeters (TLD's), to determine the absorbed dose in a region of interest within an electronic device irradiated using a Co-60 source.
Committee |
E 10
|
DocumentType |
Redline
|
Pages |
20
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1This practice covers recommended procedures for the use of dosimeters, such as thermoluminescent dosimeters (TLD's), to determine the absorbed dose in a region of interest within an electronic device irradiated using a Co-60 source. Co-60 sources are commonly used for the absorbed dose testing of silicon electronic devices.
Note 1:This absorbed-dose testing is sometimes called “total dose testing” to distinguish it from “dose rate testing.” Note 2:The effects of ionizing radiation on some types of electronic devices may depend on both the absorbed dose and the absorbed dose rate; that is, the effects may be different if the device is irradiated to the same absorbed-dose level at different absorbed-dose rates. Absorbed-dose rate effects are not covered in this practice but should be considered in radiation hardness testing.
1.2The principal potential error for the measurement of absorbed dose in electronic devices arises from non-equilibrium energy deposition effects in the vicinity of material interfaces.
1.3Information is given about absorbed-dose enhancement effects in the vicinity of material interfaces. The sensitivity of such effects to low energy components in the Co-60 photon energy spectrum is emphasized.
1.4A brief description is given of typical Co-60 sources with special emphasis on the presence of low energy components in the photon energy spectrum output from such sources.
1.5Procedures are given for minimizing the low energy components of the photon energy spectrum from Co-60 sources, using filtration. The use of a filter box to achieve such filtration is recommended.
1.6Information is given on absorbed-dose enhancement effects that are dependent on the device orientation with respect to the Co-60 source.
1.7The use of spectrum filtration and appropriate device orientation provides a radiation environment whereby the absorbed dose in the sensitive region of an electronic device can be calculated within defined error limits without detailed knowledge of either the device structure or of the photon energy spectrum of the source, and hence, without knowing the details of the absorbed-dose enhancement effects.
1.8The recommendations of this practice are primarily applicable to piece-part testing of electronic devices. Electronic circuit board and electronic system testing may introduce problems that are not adequately treated by the methods recommended here.
1.9This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
04/30118688 DC : DRAFT AUG 2004 | BS ISO ASTM 51707 - GUIDE FOR ESTIMATING UNCERTAINTIES IN DOSIMETRY FOR RADIATION PROCESSING |
12/30251712 DC | BS ISO/ASTM 52116. Practice for dosimetry for a self-contained dry-storage gamma-ray irradiator |
ASTM E 1250 : 2015 : REDLINE | Standard Test Method for Application of Ionization Chambers to Assess the Low Energy Gamma Component of Cobalt-60 Irradiators Used in Radiation-Hardness Testing of Silicon Electronic Devices |
ASTM E 666 : 2014 : REDLINE | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
ASTM E 1894 : 2013-07 | GUIDE FOR SELECTING DOSIMETRY SYSTEMS FOR APPLICATION IN PULSED X-RAY SOURCES |
ASTM F 996 : 2011 | Standard Test Method for Separating an Ionizing Radiation-Induced MOSFET Threshold Voltage Shift Into Components Due to Oxide Trapped Holes and Interface States Using the Subthreshold Current-Voltage Characteristics |
MIL-STD-883 Revision K:2016 | TEST METHOD STANDARD - MICROCIRCUITS |
03/300862 DC : DRAFT JAN 2003 | ISO/ASTM 51400 - PRACTICE FOR CHARACTERIZATION AND PERFORMANCE OF A HIGH-DOSE RADIATION DOSIMETRY CALIBRATION LABORATORY |
MIL-HDBK-817 Base Document:1994 | SYSTEM DEVELOPMENT RADIATION HARDNESS ASSURANCE |
ISO/ASTM 52116:2013 | Practice for dosimetry for a self-contained dry-storage gamma irradiator |
BS ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
ASTM E 2116 : 2013 | PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR |
ASTM F 1467 : 2011-10 | GUIDE FOR USE OF AN X-RAY TESTER ([APPROXIMATE] 10 KEV PHOTONS) IN IONIZING RADIATION EFFECTS TESTING OF SEMICONDUCTOR DEVICES AND MICROCIRCUITS |
MIL-STD-750-1 Revision A:2015 | Environmental Test Methods for Semiconductor Devices Part 1: Test Methods 1000 Through 1999 |
ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
BS ISO 15560:1998 | Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory |
ASTM F 996 : 2011 : R2018 | Standard Test Method for Separating an Ionizing Radiation-Induced MOSFET Threshold Voltage Shift Into Components Due to Oxide Trapped Holes and Interface States Using the Subthreshold Current–Voltage Characteristics (Withdrawn 2023) |
ISO 15560:1998 | Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory |
ASTM F 1190 : 2018 : REDLINE | Standard Guide for Neutron Irradiation of Unbiased Electronic Components |
ASTM E 1854 : 2013 : REDLINE | Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts |
ISO/ASTM 51400:2003 | Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
ASTM E 1250 : 2015 : REDLINE | Standard Test Method for Application of Ionization Chambers to Assess the Low Energy Gamma Component of Cobalt-60 Irradiators Used in Radiation-Hardness Testing of Silicon Electronic Devices |
ASTM E 666 : 2014 : REDLINE | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.