Standard Test Method for Application of Ionization Chambers to Assess the Low Energy Gamma Component of Cobalt-60 Irradiators Used in Radiation-Hardness Testing of Silicon Electronic Devices

Available format(s)

PDF

Language(s)

English

Published date

01-06-2015

€67.30
Excluding VAT

CONTAINED IN VOL. 12.02, 2015 Defines procedures for the use of a specialized ionization chamber to determine a figure of merit for the relative importance of such effects.

Committee
E 10
DocumentType
Redline
Pages
13
PublisherName
American Society for Testing and Materials
Status
Current

1.1Low energy components in the photon energy spectrum of Co-60 irradiators lead to absorbed dose enhancement effects in the radiation-hardness testing of silicon electronic devices. These low energy components may lead to errors in determining the absorbed dose in a specific device under test. This method covers procedures for the use of a specialized ionization chamber to determine a figure of merit for the relative importance of such effects. It also gives the design and instructions for assembling this chamber.

1.2This method is applicable to measurements in Co-60 radiation fields where the range of exposure rates is 7 × 10 −6 to 3 × 10−2 C kg −1 s−1 (approximately 100 R/h to 100 R/s). For guidance in applying this method to radiation fields where the exposure rate is >100 R/s, see Appendix X1.

Note 1:See Terminology E170 for definition of exposure and its units.

1.3The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 1249 : 2015 : REDLINE Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources
MIL-STD-883 Revision K:2016 TEST METHOD STANDARD - MICROCIRCUITS
03/300862 DC : DRAFT JAN 2003 ISO/ASTM 51400 - PRACTICE FOR CHARACTERIZATION AND PERFORMANCE OF A HIGH-DOSE RADIATION DOSIMETRY CALIBRATION LABORATORY
MIL-HDBK-817 Base Document:1994 SYSTEM DEVELOPMENT RADIATION HARDNESS ASSURANCE
MIL-STD-750-1 Revision A:2015 Environmental Test Methods for Semiconductor Devices Part 1: Test Methods 1000 Through 1999
BS ISO 15560:1998 Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory
ISO 15560:1998 Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory
ASTM F 1190 : 2018 : REDLINE Standard Guide for Neutron Irradiation of Unbiased Electronic Components
ASTM E 1854 : 2013 : REDLINE Standard Practice for Ensuring Test Consistency in Neutron-Induced Displacement Damage of Electronic Parts
ISO/ASTM 51400:2003 Practice for characterization and performance of a high-dose radiation dosimetry calibration laboratory

ASTM E 170 : 2017 : REDLINE Standard Terminology Relating to Radiation Measurements and Dosimetry
ASTM E 668 : 2013 : REDLINE Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices
ASTM E 1249 : 2015 : REDLINE Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.