Standard Practice for Use of a Radiochromic Optical Waveguide Dosimetry System
Hardcopy , PDF
15-03-2002
English
05-04-2004
CONTAINED IN VOL. 12.02, 2001 Establishes handling, testing, and procedure for using a radio chromic optical wave guide dosimetry system to measure absorbed dose in materials irradiated by photons in terms of absorbed dose in water.
Committee |
E 61
|
DocumentType |
Standard
|
Pages |
5
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
1.1 This practice covers the procedures for handling, testing, and using a radiochromic optical waveguide dosimetry system to measure absorbed dose in materials irradiated by photons in terms of absorbed dose in water.
1.2 This practice applies to radiochromic optical waveguide dosimeters that can be used within part or all of the specified ranges as follows:
1.2.1 The absorbed dose range is from 1 to 10 000 Gy for photons.
1.2.2 The absorbed dose rate is from 0.001 to 1000 Gy/s.
1.2.3 The radiation energy range for photons is from 0.1 to 10 MeV.
1.2.4 The irradiation temperature range is from -78 to +60°C.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standards | Relationship |
ISO 15556:1998 | Corresponds |
BS ISO 15559:1998 | Identical |
ISO 15557:1998 | Corresponds |
ISO 15559:1998 | Corresponds |
ISO 15558:1998 | Corresponds |
ISO 15565:1998 | Practice for use of a radiochromic liquid dosimetry system |
BS ISO 15556:1998 | Guide for selection and calibration of dosimetry systems for radiation processing |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
BS ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
ASTM E 1702 : 2013 | PRACTICE FOR DOSIMETRY IN A GAMMA IRRADIATION FACILITY FOR RADIATION PROCESSING |
ASTM E 1608 : 2015 | Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV |
ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
BS ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
BS ISO 15554:1998 | Practice for dosimetry in gamma irradiation facilities for food processing |
ASTM E 2116 : 2013 | PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR |
ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
ISO 15554:1998 | Practice for dosimetry in gamma irradiation facilities for food processing |
BS ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
ISO 15562:1998 | Practice for dosimetry in electron and bremsstrahlung irradiation facilities for food processing |
BS ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
BS ISO 15562:1998 | Practice for dosimetry in electron and bremsstrahlung irradiation facilities for food processing |
ASTM E 1431 : 2005 | PRACTICE FOR DOSIMETRY IN ELECTRON AND BREMSSTRAHLUNG IRRADIATION FACILITIES FOR FOOD PROCESSING |
BS ISO 15565:1998 | Practice for use of a radiochromic liquid dosimetry system |
ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
ASTM E 1540 : 2004 | Standard Practice for Use of a Radiochromic Liquid Dosimetry System |
ASTM E 1275 : 2013 | Standard Practice for Use of a Radiochromic Film Dosimetry System |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM E 1276 : 2012 | PRACTICE FOR USE OF A POLYMETHYLMETHACRYLATE DOSIMETRY SYSTEM |
ASTM E 1205 : 2009 | PRACTICE FOR USE OF A CERIC-CEROUS SULFATE DOSIMETRY SYSTEM |
ASTM E 275 : 2008 | Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers |
ASTM E 1026 : 2015 : REDLINE | Standard Practice for Using the Fricke Dosimetry System |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
ASTM E 666 : 2014 : REDLINE | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
ASTM E 958 : 2013 : REDLINE | Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.