1.1 This test method utilizes a laboratory space so arranged that it simulates a pair of horizontally adjacent small offices or rooms separated by a partition and sharing a common plenum space. The partition either extends to the underside of a common plenum space or penetrates through it. In the prescribed configuration, special design features of the facility ensure that the only significant sound transmission path is by way of the ceiling and the plenum space
1.2 Within the limitations outlined in the significance statement, the primary quantity measured by this test method is the ceiling attenuation of a suspended ceiling installed in a laboratory environment. By accounting for receiving room sound absorption, the normalized ceiling attenuation may be determined.
1.3 The test method may also be used to evaluate the attenuation of composite ceiling systems comprised of the ceiling material and other components such as luminaires and ventilating systems.
1.4 The field performance of a ceiling system may differ significantly from the results obtained by this test method (see Section , Significance and Use, and Test Method E 336).
1.5 The procedures may also be used to study the additional sound insulation that may be achieved by other attenuation measures. This would include materials used either as plenum barriers or as backing for all or part of the ceiling.
1.6 The facility may also be used to study the performance of an integrated system comprising plenum, ceiling, and partition, tested as a single assembly.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 90 : 2009 : R2016 | Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements |
ASTM E 1374 : 2018 : EDT 1 | Standard Guide for Office Acoustics and Applicable ASTM Standards |
ASTM E 2235 : 2004 : R2012 | Standard Test Method for Determination of Decay Rates for Use in Sound Insulation Test Methods |
ASTM E 413 : 2016 | Classification for Rating Sound Insulation |
ASTM E 2179 : 2003 : R2016 | Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors |
ASTM E 966 : 2018 : REV A | Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements |
ASTM C 634 : 2013 : EDT 1 | Standard Terminology Relating to Building and Environmental Acoustics |
ASTM E 1007 : 2019 | Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures |
ASTM E 1264 : 2014 | Standard Classification for Acoustical Ceiling Products |
ASTM E 2964 : 2019 | Standard Test Method for Measurement of the Normalized Insertion Loss of Doors |
ASTM E 492 : 2009 : R2016 : EDT 1 | Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.