• There are no items in your cart

ASTM E 1421 : 1999 : R2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-03-2009

€74.48
Excluding VAT

CONTAINED IN VOL. 03.06, 2015 Specifies two levels of tests to measure the performance of laboratory Fourier transform mid-infrared (FT-MIR) spectrometers equipped with a standard sample holder used for transmission measurements.

Committee
E 13
DocumentType
Standard Practice
Pages
12
ProductNote
Reconfirmed 2009
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This practice describes two levels of tests to measure the performance of laboratory Fourier transform mid-infrared (FT-MIR) spectrometers equipped with a standard sample holder used for transmission measurements.

1.2 This practice is not directly applicable to Fourier transform infrared (FT-IR) spectrometers equipped with various specialized sampling accessories such as flow cells or reflectance optics, nor to Fourier transform near-infrared (FT-NIR) spectrometers, nor to FT-IR spectrometers run in step scan mode.

1.2.1 If the specialized sampling accessory can be removed and replaced with a standard transmission sample holder, then this practice can be used. However, the user should recognize that the performance measured may not reflect that which is achieved when the specialized accessory is in use.

1.2.2 If the specialized sampling accessory cannot be removed, then it may be possible to employ a modified version of this practice to measure spectrometer performance. The user is referred to Guide E 1866 for a discussion of how these tests may be modified.

1.2.3 Spectrometer performance tests for FT-NIR spectrometers are described in Practice E 1944.

1.2.4 Performance tests for dispersive MIR instruments are described in Practice E 932.

1.2.5 For FT-IR spectrometers run in a step scan mode, variations on this practice and information provided by the instrument vendor should be used.

ASTM E 1866 : 1997 : R2013 Standard Guide for Establishing Spectrophotometer Performance Tests
ASTM E 1944 : 1998 : R2013 Standard Practice for Describing and Measuring Performance of Laboratory Fourier Transform Near-Infrared (FT-NIR) Spectrometers: Level Zero and Level One Tests
ASTM D 5576 : 2000 : R2013 Standard Practice for Determination of Structural Features in Polyolefins and Polyolefin Copolymers by Infrared Spectrophotometry (FT-IR)
ASTM D 6047 : 2017 Standard Test Methods for Rubber, Raw—Determination of 5-Ethylidenenorbornene (ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Terpolymers
ASTM E 168 : 2016 Standard Practices for General Techniques of Infrared Quantitative Analysis
ASTM E 1655 : 2017 Standard Practices for Infrared Multivariate Quantitative Analysis
ASTM D 7214 : 2007 : REV A : R2012 Standard Test Method for Determination of the Oxidation of Used Lubricants by FT-IR Using Peak Area Increase Calculation
ASTM E 2937 : 2018 Standard Guide for Using Infrared Spectroscopy in Forensic Paint Examinations
ASTM E 1865 : 1997 : R2013 Standard Guide for Open-Path Fourier Transform Infrared (OP/FT-IR) Monitoring of Gases and Vapors in Air
ASTM E 3085 : 2017 Standard Guide for Fourier Transform Infrared Spectroscopy in Forensic Tape Examinations
ASTM E 2412 : 2010 : R2018 Standard Practice for Condition Monitoring of In-Service Lubricants by Trend Analysis Using Fourier Transform Infrared (FT-IR) Spectrometry
ASTM E 1252 : 1998 : R2013 : EDT 1 Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis
ASTM E 2224 : 2019 Standard Guide for Forensic Analysis of Fibers by Infrared Spectroscopy
ASTM D 5670 : 1995 : R2019 Standard Test Method for Rubber—Determination of Residual Unsaturation in Hydrogenated Nitrile Rubber (HNBR) by Infrared Spectrophotometry
ASTM D 6645 : 2018 Standard Test Method for Methyl (Comonomer) Content in Polyethylene by Infrared Spectrophotometry
ASTM E 2105 : 2000 : R2016 Standard Practice for General Techniques of Thermogravimetric Analysis (TGA) Coupled With Infrared Analysis (TGA/IR)
ASTM E 1642 : 2000 : R2016 Standard Practice for General Techniques of Gas Chromatography Infrared (GC/IR) Analysis
ASTM F 2381 : 2010 Standard Test Method for Evaluating Trans-Vinylene Yield in Irradiated Ultra-High-Molecular-Weight Polyethylene Fabricated Forms Intended for Surgical Implants by Infrared Spectroscopy
ASTM E 1982 : 1998 : R2013 Standard Practice for Open-Path Fourier Transform Infrared (OP/FT-IR) Monitoring of Gases and Vapors in Air
ASTM E 2106 : 2000 : R2011 Standard Practice for General Techniques of Liquid Chromatography-Infrared (LC/IR) and Size Exclusion Chromatography-Infrared (SEC/IR) Analyses
ASTM E 2056 : 2004 : R2016 Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses, Calibrated Using Surrogate Mixtures
ASTM D 7418 : 2012 Standard Practice for Set-Up and Operation of Fourier Transform Infrared (FT-IR) Spectrometers for In-Service Oil Condition Monitoring

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.