ASTM E 1607 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Use of the Alanine-EPR Dosimetry System
Hardcopy , PDF
24-05-2024
English
21-01-2014
CONTAINED IN VOL. 12.02, 2001 Establishes materials description, dosimeter preparation, instrumentation and procedures for the use of alanine-EPR dosimetry system for measurement of the absorbed dose in materials irradiated with photons and electrons.
Committee |
E 61
|
DocumentType |
Standard
|
Pages |
7
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This practice covers dosimeter materials, instrumentation, and procedures for using the alanine-EPR dosimetry system for measuring the absorbed dose in the photon and electron radiation processing of materials. The system is based on electron paramagnetic resonance (EPR) spectroscopy of free radicals derived from the amino acid alanine.
1.2 The alanine dosimeter is classified as a type I dosimeter as it is affected by individual influence quantities in a well-defined way that can be expressed in terms of independent correction factors (see ASTM Practice E2628). The alanine dosimeter may be used in either a reference standard dosimetry system or in a routine dosimetry system.
1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM E2628 “Practice for Dosimetry in Radiation Processing” for alanine dosimetry system. It should be read in conjunction with ASTM E2628.
1.4 This practice covers alanine-EPR dosimetry systems for dose measurements under the following conditions:
1.4.1 The absorbed dose range is between 1 and 1.5 × 105Gy.
1.4.2 The absorbed dose rate is up to 102Gy s-1 for continuous radiation fields and up to 3 × 1010Gy s-1 for pulsed radiation fields (1-4).
1.4.3 The radiation energy for photons and electrons is between 0.1 and 30 MeV (1, 2, 5-8).
1.4.4 The irradiation temperature is between –78 °C and + 70 °C (2, 9-12).
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standards | Relationship |
ISO 15556:1998 | Corresponds |
ISO 15557:1998 | Corresponds |
ISO 15566:1998 | Corresponds |
ISO 15558:1998 | Corresponds |
BS ISO 15573:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 80 keV and 300 keV |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
ISO 15573:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 80 keV and 300 keV |
BS ISO 15556:1998 | Guide for selection and calibration of dosimetry systems for radiation processing |
ASTM E 1205 : 2009 | PRACTICE FOR USE OF A CERIC-CEROUS SULFATE DOSIMETRY SYSTEM |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 1276 : 2012 | PRACTICE FOR USE OF A POLYMETHYLMETHACRYLATE DOSIMETRY SYSTEM |
BS ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
ASTM E 1940 : 2013 | Standard Guide for Dosimetry for Sterile Insect Release Programs |
ASTM E 1702 : 2013 | PRACTICE FOR DOSIMETRY IN A GAMMA IRRADIATION FACILITY FOR RADIATION PROCESSING |
ASTM E 1608 : 2015 | Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV |
BS ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
ASTM E 1900 : 2009 | GUIDE FOR DOSIMETRY IN RADIATION RESEARCH ON FOOD AND AGRICULTURAL PRODUCTS |
ASTM E 2116 : 2013 | PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR |
ASTM E 1939 : 2005 | Standard Practice for Blood Irradiation Dosimetry |
ISO 15571:1998 | Practice for dosimetry in a gamma irradiation facility for radiation processing |
BS ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
BS ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
ISO 15572:1998 | Guide for estimating uncertainties in dosimetry for radiation processing |
BS ISO 15558:1998 | Practice for use of a polymethylmethacrylate dosimetry system |
ASTM E 1431 : 2005 | PRACTICE FOR DOSIMETRY IN ELECTRON AND BREMSSTRAHLUNG IRRADIATION FACILITIES FOR FOOD PROCESSING |
BS ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
ISO 15567:1998 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing |
ASTM E 1818 : 2013 | PRACTICE FOR DOSIMETRY IN AN ELECTRON BEAM FACILITY FOR RADIATION PROCESSING AT ENERGIES BETWEEN 80 AND 300 KEV |
ASTM E 1540 : 2004 | Standard Practice for Use of a Radiochromic Liquid Dosimetry System |
ASTM E 1431 : 2005 | PRACTICE FOR DOSIMETRY IN ELECTRON AND BREMSSTRAHLUNG IRRADIATION FACILITIES FOR FOOD PROCESSING |
ASTM E 2628 : 2009 | Standard Practice for Dosimetry for Radiation Processing |
ASTM E 170 : 2020 | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
ASTM E 170 : 2023 | Standard Terminology Relating to Radiation Measurements and Dosimetry |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.