ASTM E 1631 : 2013
Superseded
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PRACTICE FOR USE OF CALORIMETRIC DOSIMETRY SYSTEMS FOR ELECTRON BEAM DOSE MEASUREMENTS AND DOSIMETER CALIBRATIONS
Available format(s)
PDF
Language(s)
English
Published date
01-01-2013
Superseded date
03-12-2024
Superseded by
€65.37
Excluding VAT
CONTAINED IN VOL. 12.02, 2001 Establishes methods for the preparation and use of semi-adiabatic calorimeters for measurement of absorbed dose in graphite, water, or polystyrene when irradiated with electrons.
| Committee |
E 10
|
| DocumentType |
Standard
|
| Pages |
9
|
| PublisherName |
American Society for Testing and Materials
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| ISO 15556:1998 | Corresponds |
| ISO 15557:1998 | Corresponds |
| ISO 15568:1998 | Identical |
| ISO 15558:1998 | Corresponds |
| BS ISO 15558:1998 | Practice for use of a polymethylmethacrylate dosimetry system |
| BS ISO 15556:1998 | Guide for selection and calibration of dosimetry systems for radiation processing |
| ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
| ASTM E 1276 : 2012 | PRACTICE FOR USE OF A POLYMETHYLMETHACRYLATE DOSIMETRY SYSTEM |
| BS ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
| ISO 15570:1998 | Practice for use of cellulose acetate dosimetry system |
| ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
| ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
| ASTM E 1431 : 2005 | PRACTICE FOR DOSIMETRY IN ELECTRON AND BREMSSTRAHLUNG IRRADIATION FACILITIES FOR FOOD PROCESSING |
| BS ISO 15569:1998 | Practice for dosimetry in an electron-beam facility for radiation processing at energies between 300 keV and 25 MeV |
| ASTM E 1431 : 2005 | PRACTICE FOR DOSIMETRY IN ELECTRON AND BREMSSTRAHLUNG IRRADIATION FACILITIES FOR FOOD PROCESSING |
| ASTM E 2628 : 2009 | Standard Practice for Dosimetry for Radiation Processing |
| ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
| ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
| ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
| ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
| ASTM E 666 : 2014 : REDLINE | Standard Practice for Calculating Absorbed Dose From Gamma or X Radiation |
| ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
Summarise