• ASTM E 1661 : 1995 : REV A : R2018

    Current The latest, up-to-date edition.

    Standard Classification for Serviceability of an Office Facility for Meetings and Group Effectiveness

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-03-2018

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 04.11, 2018 Defines pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements to enable work groups or project groups to function effectively and productively.

    Scope - (Show below) - (Hide below)

    1.1This classification covers pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements to enable work groups or project groups to function effectively and productively.

    1.2Within that aspect of serviceability, each pair of scales, shown in Figs. 1-4, are for classifying one topic of serviceability. Each paragraph in an Occupant Requirement Scale (see Figs. 1-4) summarizes one level of serviceability on that topic, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1-4) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability.

    FIG. 1 Scale A.2.1 for Meeting and Conference Rooms

     Scale A.2.1 for Meeting and Conference Rooms Scale A.2.1 for Meeting and Conference Rooms

    FIG. 1 Scale A.2.1 for Meeting and Conference Rooms (continued)

     Scale A.2.1 for Meeting and Conference Rooms Scale A.2.1 for Meeting and Conference Rooms

    FIG. 1 Scale A.2.1 for Meeting and Conference Rooms (continued)

     Scale A.2.1 for Meeting and Conference Rooms Scale A.2.1 for Meeting and Conference Rooms

    FIG. 2 Scale A.2.2 for Informal Meetings and Interaction

     Scale A.2.2 for Informal Meetings and Interaction Scale A.2.2 for Informal Meetings and Interaction

    FIG. 2 Scale A.2.2 for Informal Meetings and Interaction (continued)

     Scale A.2.2 for Informal Meetings and Interaction Scale A.2.2 for Informal Meetings and Interaction

    FIG. 3 Scale A.2.3 for Group Layout and Territory

     Scale A.2.3 for Group Layout and Territory Scale A.2.3 for Group Layout and Territory

    FIG. 3 Scale A.2.3 for Group Layout and Territory (continued)

     Scale A.2.3 for Group Layout and Territory Scale A.2.3 for Group Layout and Territory

    FIG. 4 Scale A.2.4 for Group Workrooms

     Scale A.2.4 for Group Workrooms Scale A.2.4 for Group Workrooms

    FIG. 4 Scale A.2.4 for Group Workrooms (continued)

     Scale A.2.4 for Group Workrooms Scale A.2.4 for Group Workrooms

    1.3The entries in the Facility Rating Scale (see Figs. 1-4) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing.

    1.4This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared.

    1.5This classification indicates what would cause a facility to be rated at a certain level of serviceability but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1334. The scales in this classification are complimentary to and compatible with Practice E1334. Each requires the other.

    1.6The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

    1.7This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

    General Product Information - (Show below) - (Hide below)

    Committee E 06
    Document Type Standard
    Product Note Reconfirmed 2018
    Publisher American Society for Testing and Materials
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    ASTM E 1765 : 2016 Standard Practice for Applying Analytical Hierarchy Process (AHP) to Multiattribute Decision Analysis of Investments Related to Projects, Products, and Processes

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
    ASTM E 1679 : 2013 : R2019 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
    ISO 6240:1980 Performance standards in building Contents and presentation
    ASTM E 1679 : 1995 : R2012 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
    ASHRAE 62 : 2001 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
    ASTM E 1679 : 1995 : R1999 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
    ASTM E 1679 : 1995 : R2005 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
    ASTM E 1334 : 1995 : R2005 Standard Practice for Rating the Serviceability of a Building or Building-Related Facility
    ASHRAE 55 : 2017 THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY
    ASTM E 1679 : 2013 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
    ASTM E 1679 : 2013 : REDLINE Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
    ASTM E 1334 : 1995 : R1999 Standard Practice for Rating the Serviceability of a Building or Building-Related Facility
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective