• There are no items in your cart

ASTM E 1692 : 1995 : REV A : R2018

Current

Current

The latest, up-to-date edition.

Standard Classification for Serviceability of an Office Facility for Change and Churn by Occupants

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-03-2018

€61.92
Excluding VAT

CONTAINED IN VOL. 04.11, 2018 Defines pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements to accommodate changes in working method, and frequent relocations of staff, and realignment of workstations.

Committee
E 06
DocumentType
Standard
Pages
11
ProductNote
Reconfirmed 2018
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This classification covers pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements to accommodate changes in working method, and frequent relocations of staff, and realignment of workstations.

1.2Each pair of scales shown in Figs. 1-5, printed side by side on a page, are for classifying one topic of serviceability within that aspect of serviceability. Each paragraph in an Occupant Requirement Scale (see Figs. 1-5) summarizes one level of serviceability on that topic that occupants might require. The matching entry in the Facility Rating Scale (see) is a translation of the requirement into a description of certain features of a facility that, taken in combination, indicate that the facility is likely to meet that level of required serviceability.

FIG. 1Scale A.6.1 for Disruption Due to Physical Change

Scale A.6.1 for Disruption Due to Physical ChangeScale A.6.1 for Disruption Due to Physical Change

FIG. 1Scale A.6.1 for Disruption Due to Physical Change (continued)

Scale A.6.1 for Disruption Due to Physical ChangeScale A.6.1 for Disruption Due to Physical Change

FIG. 2Scale A.6.2 for Illumination, HVAC, and Sprinklers

Scale A.6.2 for Illumination, HVAC, and SprinklersScale A.6.2 for Illumination, HVAC, and Sprinklers

FIG. 2Scale A.6.2 for Illumination, HVAC, and Sprinklers (continued)

Scale A.6.2 for Illumination, HVAC, and SprinklersScale A.6.2 for Illumination, HVAC, and Sprinklers

FIG. 3Scale A.6.3 for Minor Changes to Layout

Scale A.6.3 for Minor Changes to LayoutScale A.6.3 for Minor Changes to Layout

FIG. 3Scale A.6.3 for Minor Changes to Layout (continued)

Scale A.6.3 for Minor Changes to LayoutScale A.6.3 for Minor Changes to Layout

FIG. 4Scale A.6.4 for Partition Wall Relocations

Scale A.6.4 for Partition Wall RelocationsScale A.6.4 for Partition Wall Relocations

FIG. 4Scale A.6.4 for Partition Wall Relocations (continued)

Scale A.6.4 for Partition Wall RelocationsScale A.6.4 for Partition Wall Relocations

FIG. 5 Scale A.6.5 for Lead Time for Facilities Group

 Scale A.6.5 for Lead Time for Facilities Group Scale A.6.5 for Lead Time for Facilities Group

FIG. 5 Scale A.6.5 for Lead Time for Facilities Group (continued)

 Scale A.6.5 for Lead Time for Facilities Group Scale A.6.5 for Lead Time for Facilities Group

1.3The entries in the Facility Rating Scale (see Figs. 1-5) are indicative and not comprehensive. They are for quick scanning, to estimate approximately, quickly, and economically how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, and evaluating how an office facility is performing.

1.4This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared.

1.5This classification indicates what would cause a facility to be rated at a certain level of serviceability, but it does not state how to conduct a serviceability rating or how to assign a serviceability score. That information is found in Practice E1334. The scales in this classification are complementary to and compatible with Practice E1334. Each requires the other.

1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E 1765 : 2016 Standard Practice for Applying Analytical Hierarchy Process (AHP) to Multiattribute Decision Analysis of Investments Related to Projects, Products, and Processes

ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ASTM E 1679 : 2013 : R2019 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
ISO 6240:1980 Performance standards in building Contents and presentation
ASTM E 1679 : 1995 : R2012 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
ASTM E 631 : 2015 : R2024 Standard Terminology of Building Constructions
ASTM E 1679 : 1995 : R1999 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
ASTM E 1679 : 1995 : R2005 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
ASTM E 631 : 2015 Standard Terminology of Building Constructions
ASTM E 1334 : 1995 : R2005 Standard Practice for Rating the Serviceability of a Building or Building-Related Facility
ASTM E 1679 : 2013 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
ISO 7162:1992 Performance standards in building Contents and format of standards for evaluation of performance
ASTM E 1679 : 2013 : REDLINE Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility, and for Determining What Serviceability is Provided or Proposed
ASTM E 1334 : 1995 : R1999 Standard Practice for Rating the Serviceability of a Building or Building-Related Facility

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.