• ASTM E 1695 : 1995

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Standard Test Method for Measurement of Computed Tomography (CT) System Performance

    Available format(s):  Hardcopy, PDF

    Superseded date:  11-11-2014

    Language(s):  English

    Published date:  01-01-2001

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 03.03, 2017 Gives instruction for determining the spatial resolution and contrast sensitivity in X-ray and g-ray computed tomography (CT) images.

    Scope - (Show below) - (Hide below)

    1.1 This test method provides instruction for determining the spatial resolution and contrast sensitivity in X-ray and -ray computed tomography (CT) images. The determination is based on examination of the CT image of a uniform disk of material. The spatial resolution measurement is derived from an image analysis of the sharpness at the edge of the disk. The contrast sensitivity measurement is derived from an image analysis of the statistical noise at the center of the disk.

    1.2 This test method is more quantitative and less susceptible to interpretation than alternative approaches because the required disk is easy to fabricate and the analysis is immune to cupping artifacts. This test method may not yield meaningful results if the disk image occupies less than a significant fraction of the field of view.

    1.3 This test method may also be used to evaluate other performance parameters. Among those characteristics of a CT system that are detectable with this test method are: the mid-frequency enhancement of the reconstruction kernel, the presence (or absence) of detector crosstalk, the undersampling of views, and the clipping of unphysical (that is, negative) CT numbers (see Air Force Technical Report WL-TR-94-4021). It is highly likely that other characteristics as well can be detected with this test method.

    1.4 The values stated in SI units are to be regarded as the standard. Inch-pound units are provided for information only.

    1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    General Product Information - (Show below) - (Hide below)

    Committee E 07
    Document Type Test Method
    Publisher American Society for Testing and Materials
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    ASTM E 1814 : 2014 Standard Practice for Computed Tomographic (CT) Examination of Castings
    I.S. EN 61223-2-6:2007 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-6: CONSTANCY TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
    17/30334746 DC : 0 BS EN 62945 - RADIATION PROTECTION INSTRUMENTATION - MEASURING THE IMAGING PERFORMANCE OF X-RAY COMPUTED TOMOGRAPHY (CT) SECURITY-SCREENING SYSTEMS
    03/304751 DC : DRAFT APR 2003 IEC 61223-3-5 ED.1.0 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-5: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
    ASTM C 1175 : 1999 : REV A : R2004 Standard Guide to Test Methods and Standards for Nondestructive Testing of Advanced Ceramics
    IEC 61223-3-5:2004 Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment
    BS EN 61223-3-5:2004 Evaluation and routine testing in medical imaging departments Acceptance tests - Imaging performance of computed tomography X-ray equipment
    04/30124942 DC : DRAFT NOV 2004 BS EN 61223-2-6 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-6: CONSTANCY TESTS - X-RAY EQUIPMENT FOR COMPUTED TOMOGRAPHY
    I.S. EN 61223-3-5:2004 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-5: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
    IEC 61223-2-6:2006 Evaluation and routine testing in medical imaging departments ­ - Part 2­-6: Constancy tests ­ imaging performance of computed tomography X-ray equipment
    BS EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments Constancy tests. Imaging performance of computed tomography X-ray equipment
    ASTM C 1175 : 1999 : REV A : R2010 Standard Guide to Test Methods and Standards for Nondestructive Testing of Advanced Ceramics (Withdrawn 2018)
    IEEE N42.45-2011 American National Standard for Evaluating the Image Quality of X-ray Computed Tomography (CT)Security-Screening Systems
    ASTM E 1570 : 2011 : REDLINE PRACTICE FOR COMPUTED TOMOGRAPHIC (CT) EXAMINATION
    ASTM E 1814 : 2014 : REDLINE Standard Practice for Computed Tomographic (CT) Examination of Castings
    ASTM C 1175 : 1999 : REV A Standard Guide to Test Methods and Standards for Nondestructive Testing of Advanced Ceramics
    EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments - Part 2-6: Constancy tests - Imaging performance of computed tomography X-ray equipment
    EN 61223-3-5:2004 Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment

    Standards Referencing This Book - (Show below) - (Hide below)

    ASTM E 1441 : 2011 : REDLINE Standard Guide for Computed Tomography (CT) Imaging
    ASTM E 1570 : 2011 : REDLINE PRACTICE FOR COMPUTED TOMOGRAPHIC (CT) EXAMINATION
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective