ASTM E 1864 : 2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Standard Practice for Evaluating Quality Systems of Organizations Conducting Facility and Hazard Assessments for Lead in Paint, Dust, Airborne Particulate, and Soil in and around Buildings and Related Structures (Withdrawn 2011)
Hardcopy , PDF
01-01-2011
English
10-07-2002
CONTAINED IN VOL. 04.12, 2009 Describes quality system requirements, competency and qualifications for inclusion of minimum requirements for training, sampling design, personnel and equipment, duties, responsibilities and services in respect of organizations providing lead assessment services for determination of the extent of lead and lead-based paint contamination.
Committee |
E 06
|
DevelopmentNote |
Supersedes ASTM PS 45 (10/2004)
|
DocumentType |
Standard Practice
|
Pages |
7
|
PublisherName |
American Society for Testing and Materials
|
Status |
Withdrawn
|
Supersedes |
1.1 This practice covers the quality system requirements, competency and qualifications, to include minimum requirements for training, sampling design, personnel and equipment, duties, responsibilities, and services of organizations engaged in providing lead assessment services to determine the extent of lead and lead-based paint contamination.
1.2 Organizations evaluated using this practice shall engage in one or more of the following assessment activities: sampling design, sample collection, field testing, data validation, and report writing and recommendations.
1.3 This practice has been developed consistent with the appropriate requirements of Guide E 994 and ISO 9001 and ISO Guide 25.
1.4 Where the testing function exists, it must be evaluated using Practice E 1583.
1.5 This practice is meant to be used with Guide D 4840, Practices D 5438, E 1553, E 1727, E 1728, and E 1729, and Terminology E 1605.
1.6 For information and guidance in applying this practice, see EPA 600/8-91/214 and EPA 600/R-93/200.
1.7 This practice contains notes that are explanatory and are not part of the mandatory requirements of the practice.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 2239 : 2012 : R2016 | Standard Practice for Record Keeping and Record Preservation for Lead Hazard Activities |
ASTM E 1613 : 2012 | Standard Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques (Withdrawn 2021) |
ASTM E 1775 : 2016 | Standard Guide for Evaluating Performance of On-Site Extraction and Field-Portable Electrochemical or Spectrophotometric Analysis for Lead |
ASTM E 3193 : 2019 | Standard Test Method for Measurement of Lead (Pb) in Dust by Wipe, Paint, and Soil by Flame Atomic Absorption Spectrophotometry (FAAS) |
ASTM E 2255 : 2004 | Standard Practice for Conducting Visual Assessments for Lead Hazards in Buildings (Withdrawn 2013) |
ASTM E 2052 : 1999 | Standard Guide for Evaluation, Management, and Control of Lead Hazards in Facilities (Withdrawn 2008) |
ASTM E 1775 : 2016 : REDLINE | Standard Guide for Evaluating Performance of On-Site Extraction and Field-Portable Electrochemical or Spectrophotometric Analysis for Lead |
ASTM E 2239 : 2012 | Standard Practice for Record Keeping and Record Preservation for Lead Hazard Activities |
ASTM E 1613 : 2012 : REDLINE | Standard Test Method for Determination of Lead by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), Flame Atomic Absorption Spectrometry (FAAS), or Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Techniques |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ASTM D 4840 : 1999 | Standard Guide for Sampling Chain-of-Custody Procedures |
ASTM E 994 : 1995 | Standard Guide for Calibration and Testing Laboratory Accreditation Systems General Requirements for Operation and Recognition (Withdrawn 2004) |
ASTM D 5438 : 2017 : REDLINE | Standard Practice for Collection of Floor Dust for Chemical Analysis |
ASTM E 1187 : 1997 | Standard Terminology Relating to Conformity Assessment (Withdrawn 2006) |
ASTM E 1553 : 1993 | Standard Practice for Collection of Airborne Particulate Lead During Abatement and Construction Activities (Withdrawn 2002) |
ISO/IEC Guide 25:1990 | General requirements for the competence of calibration and testing laboratories |
ASTM E 1729 : 2016 | Standard Practice for Field Collection of Dried Paint Samples for Subsequent Lead Determination |
ASTM E 1583 : 2017 | Standard Practice for Evaluating Laboratories Engaged in Determination of Lead in Paint, Dust, Airborne Particulates, and Soil Taken From and Around Buildings and Related Structures |
ISO 9001:2015 | Quality management systems — Requirements |
ASTM E 1728 : 2016 : REDLINE | Standard Practice for Collection of Settled Dust Samples Using Wipe Sampling Methods for Subsequent Lead Determination |
ASTM E 1727 : 2016 | Standard Practice for Field Collection of Soil Samples for Subsequent Lead Determination |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.