ASTM E 1940 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Dosimetry for Sterile Insect Release Programs
Hardcopy , PDF
09-09-2024
English
21-03-2014
CONTAINED IN VOL. 12.02, 2001 Covers dosimetric procedures to be followed for the radiation sterilization of live insects for use in pest management programs.
Committee |
E 61
|
DocumentType |
Standard
|
Pages |
12
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This guide outlines dosimetric procedures to be followed for the radiation-induced reproductive sterilization of live insects for use in pest management programs. The primary use of such insects is in the Sterile Insect Technique, where large numbers of reproductively sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide.
NOTE 1—Dosimetry is only one component of a total quality assurance program to ensure that irradiated insects are adequately sterilized and fully competitive or otherwise suitable for their intended purpose.
1.2 This guide provides information on dosimetry for the irradiation of insects for these types of irradiators: selfcontained dry-storage 137Cs or 60Co irradiators, self-contained low-energy X-ray irradiators (maximum processing energies from 150 to 300 keV), large-scale gamma irradiators, and electron accelerators (electron and X-ray modes).
NOTE 2—Additional, detailed information on dosimetric procedures to be followed in installation qualification, operational qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities processing at energies over 300 keV), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and 52116 (self-contained dry-storage gamma facilities), and in Ref (1)2 (self-contained X-ray facilities).
1.3 The absorbed dose for insect sterilization is typically within the range of 20 to 600 Gy.
1.4 This guide refers, throughout the text, specifically to reproductive sterilization of insects. It is equally applicable to radiation sterilization of invertebrates from other taxa (for example, Acarina, Gastropoda) and to irradiation of live insects or other invertebrates for other purposes (for example, inducing mutations), provided the absorbed dose is within the range specified in 1.3.
1.5 This guide also covers the use of radiation-sensitive indicators for the visual and qualitative indication that the insects have been irradiated.
1.6 This document is one of a set of standards that provides recommendations for properly implementing and utilizing dosimetry in radiation processing and describes a means of achieving compliance with the requirements of ASTM Practice E2628. It is intended to be read in conjunction with ASTM E2628.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 2116 : 2013 | PRACTICE FOR DOSIMETRY FOR A SELF-CONTAINED DRY-STORAGE GAMMA-RAY IRRADIATOR |
ASTM E 1275 : 2013 | Standard Practice for Use of a Radiochromic Film Dosimetry System |
ASTM E 1608 : 2015 | Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV |
ASTM E 177 : 2014 : REDLINE | Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods |
ASTM E 1539 : 2005 | Standard Guide for Use of Radiation-Sensitive Indicators |
ASTM E 2628 : 2009 | Standard Practice for Dosimetry for Radiation Processing |
ASTM E 1956 : 2013 | Standard Practice for Use of Thermoluminescence-Dosimetry (TLD) Systems for Radiation Processing |
ASTM E 1026 : 2015 : REDLINE | Standard Practice for Using the Fricke Dosimetry System |
ASTM E 2303 : 2011 | Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities |
ASTM E 1538 : 2009 | PRACTICE FOR USE OF THE ETHANOL-CHLOROBENZENE DOSIMETRY SYSTEM |
ASTM E 1607 : 2013 | Standard Practice for Use of the Alanine-EPR Dosimetry System |
ASTM E 1261 : 2013 | GUIDE FOR SELECTION AND CALIBRATION OF DOSIMETRY SYSTEMS FOR RADIATION PROCESSING |
ASTM E 1702 : 2013 | PRACTICE FOR DOSIMETRY IN A GAMMA IRRADIATION FACILITY FOR RADIATION PROCESSING |
ASTM E 1707 : 2015 | Standard Guide for Estimation of Measurement Uncertainty in Dosimetry for Radiation Processing |
ASTM E 170 : 2017 : REDLINE | Standard Terminology Relating to Radiation Measurements and Dosimetry |
ASTM E 668 : 2013 : REDLINE | Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices |
ASTM E 1540 : 2004 | Standard Practice for Use of a Radiochromic Liquid Dosimetry System |
ASTM E 2303 : 2003 | Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities |
ASTM E 2303 : 2011 : EDT 1 | Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities |
ASTM E 1649 : 2015 | Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.