ASTM E 1944 : 1998 : R2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Describing and Measuring Performance of Laboratory Fourier Transform Near-Infrared (FT-NIR) Spectrometers: Level Zero and Level One Tests
Hardcopy , PDF
27-04-2021
English
30-01-2013
CONTAINED IN VOL. 03.06, 2014 Defines two levels of tests to measure the performance of laboratory Fourier transform near infrared (FT-NIR) spectrometers.
Committee |
E 13
|
DocumentType |
Standard Practice
|
Pages |
5
|
ProductNote |
Reconfirmed 2013
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This practice covers two levels of tests to measure the performance of laboratory Fourier transform near infrared (FT-NIR) spectrometers. This practice applies to the short-wave near infrared region, approximately 800 nm (12 500 cm -1) to 1100 nm (9090.91 cm -1); and the long-wavelength near infrared region, approximately 1100 nm (9090.91 cm -1) to 2500 nm (4000 cm -1). This practice is intended mainly for transmittance measurements of gases and liquids, although it is broadly applicable for reflectance measurements.
ASTM E 1421 : 1999 : R2015 : EDT 1 | Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests |
ASTM E 1655 : 2017 | Standard Practices for Infrared Multivariate Quantitative Analysis |
ASTM E 2056 : 2004 : R2016 | Standard Practice for Qualifying Spectrometers and Spectrophotometers for Use in Multivariate Analyses, Calibrated Using Surrogate Mixtures |
ASTM D 6122 : 2020 : REV A | Standard Practice for Validation of the Performance of Multivariate Online, At-Line, Field and Laboratory Infrared Spectrophotometer, and Raman Spectrometer Based Analyzer Systems |
ASTM E 1421 : 1999 : R2004 | Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests |
ASTM E 1252 : 1998 : R2007 | Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis |
ASTM E 1252 : 1998 | Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis |
ASTM E 932 : 1989 : R2013 | Standard Practice for Describing and Measuring Performance of Dispersive Infrared Spectrometers |
ASTM E 1421 : 1999 : R2009 | Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests |
ASTM E 1421 : 1999 : R2015 : EDT 1 | Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests |
ASTM E 932 : 1989 : R2021 | Standard Practice for Describing and Measuring Performance of Dispersive Infrared Spectrometers |
ASTM E 1252 : 1998 : R2021 | Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis |
ASTM E 1421 : 1999 | Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers Level Zero and Level One Tests |
ASTM E 1252 : 1998 : R2013 : EDT 1 | Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis |
ASTM E 1252 : 1998 : R2002 | Standard Practice for General Techniques for Obtaining Infrared Spectra for Qualitative Analysis |
ASTM E 168 : 2016 | Standard Practices for General Techniques of Infrared Quantitative Analysis |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.