ASTM E 241 : 2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Limiting Water-Induced Damage to Buildings
Hardcopy , PDF
11-11-2014
English
01-11-2009
CONTAINED IN VOL. 04.11, 2014 Defines building design, construction, commissioning, operation, and maintenance.
Committee |
E 06
|
DocumentType |
Guide
|
Pages |
14
|
ProductNote |
Reconfirmed 2009
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1 This guide concerns building design, construction, commissioning, operation, and maintenance.
1.2 This guide addresses the need for systematic evaluation of factors that can result in moisture-induced damage to a building or its components. Although of great potential importance, serviceability issues which are often, but not necessarily, related to physical damage of the building or its components (for example, indoor air quality or electrical safety) are not directly addressed in this guide.
1.3 The emphasis of this guide is on low-rise buildings. Portions of this guide; in particular Sections 5, 6, and 7; may also be applicable to high-rise buildings.
1.4 This guide is not intended for direct use in codes and specifications. It does not attempt to prescribe acceptable limits of damage. Buildings intended for different uses may have different service life expectancies, and expected service lives of different components within a given building often differ. Furthermore, some building owners may be satisfied with substantially shorter service life expectancies of building components or of the entire building than other building owners. Lastly, the level of damage that renders a component unserviceable may vary with the type of component, the degree to which failure of the component is critical (for example, whether failure constitutes a life-safety hazard), and the judgement (that is, tolerance for damage) of the building owner. For the reasons stated in this paragraph, prescribing limits of damage would require listing many pages of exceptions and qualifiers and is beyond the scope of this guide.
1.5 This standard does not purport to address the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 1677 : 2011 : REDLINE | SPECIFICATION FOR AIR BARRIER (AB) MATERIAL OR SYSTEM FOR LOW-RISE FRAMED BUILDING WALLS |
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ISO 6707-1:2017 | Buildings and civil engineering works Vocabulary Part 1: General terms |
ASTM E 1105 : 2015 : REDLINE | Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference |
ASTM E 1745 : 2017 : REDLINE | Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs |
ASTM C 1193 : 2016 : REDLINE | Standard Guide for Use of Joint Sealants |
ASHRAE HDBK FUNDAMENTALS : 2013 | ASHRAE HANDBOOK - FUNDAMENTALS |
ASTM E 331 : 2000 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASCE 24 05 : 2006 | FLOOD RESISTANT DESIGN AND CONSTRUCTION |
ASHRAE 62 : 2001 | VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY |
ASTM C 168 : 2017-06 | TERMINOLOGY RELATING TO THERMAL INSULATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.