CONTAINED IN VOL. 04.11, 2014 Defines building design, construction, commissioning, operation, and maintenance.

Committee
E 06
DocumentType
Guide
Pages
14
ProductNote
Reconfirmed 2009
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This guide concerns building design, construction, commissioning, operation, and maintenance.

1.2 This guide addresses the need for systematic evaluation of factors that can result in moisture-induced damage to a building or its components. Although of great potential importance, serviceability issues which are often, but not necessarily, related to physical damage of the building or its components (for example, indoor air quality or electrical safety) are not directly addressed in this guide.

1.3 The emphasis of this guide is on low-rise buildings. Portions of this guide; in particular Sections 5, 6, and 7; may also be applicable to high-rise buildings.

1.4 This guide is not intended for direct use in codes and specifications. It does not attempt to prescribe acceptable limits of damage. Buildings intended for different uses may have different service life expectancies, and expected service lives of different components within a given building often differ. Furthermore, some building owners may be satisfied with substantially shorter service life expectancies of building components or of the entire building than other building owners. Lastly, the level of damage that renders a component unserviceable may vary with the type of component, the degree to which failure of the component is critical (for example, whether failure constitutes a life-safety hazard), and the judgement (that is, tolerance for damage) of the building owner. For the reasons stated in this paragraph, prescribing limits of damage would require listing many pages of exceptions and qualifiers and is beyond the scope of this guide.

1.5 This standard does not purport to address the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 1677 : 2011 : REDLINE SPECIFICATION FOR AIR BARRIER (AB) MATERIAL OR SYSTEM FOR LOW-RISE FRAMED BUILDING WALLS
ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ISO 6707-1:2017 Buildings and civil engineering works Vocabulary Part 1: General terms
ASTM E 1105 : 2015 : REDLINE Standard Test Method for Field Determination of Water Penetration of Installed Exterior Windows, Skylights, Doors, and Curtain Walls, by Uniform or Cyclic Static Air Pressure Difference
ASTM E 1745 : 2017 : REDLINE Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs
ASTM C 1193 : 2016 : REDLINE Standard Guide for Use of Joint Sealants
ASHRAE HDBK FUNDAMENTALS : 2013 ASHRAE HANDBOOK - FUNDAMENTALS
ASTM E 331 : 2000 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference
ASCE 24 05 : 2006 FLOOD RESISTANT DESIGN AND CONSTRUCTION
ASHRAE 62 : 2001 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
ASTM C 168 : 2017-06 TERMINOLOGY RELATING TO THERMAL INSULATION

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.