CONTAINED IN VOL. 04.12, 2014 Includes specifications for the dimensioning of custom tiled/mortared masonry heaters (stoves).
Committee |
E 06
|
DocumentType |
Standard
|
Pages |
4
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This specification contains specifications for the dimensioning of custom tiled/mortared masonry heaters (stoves). The custom tiled/mortared masonry heaters (stoves) are individually technically calculated and constructed. This information can be used for log (cordwood) wood-fired masonry heaters that burn one fuel load per storage period with a maximum load between 10 and 40 kg and a storage period (nominal heating time) between 8 and 24 h per EN 15544.
1.2This specification is valid for masonry heaters equipped with fireclay as interior material with an apparent density between 1750 and 2200 kg/m³, a degree of porosity 18 up to 33 % by volume, and a heat conductivity from 0.65 up to 0.90 W/mK (temperature range 20 to 400°C) per EN 15544.
1.3This specification is valid for masonry heaters with sidewise combustion air supply of the combustion chamber.
1.4This specification is not valid for masonry heaters combined with water heat exchangers for central heating or other heat-absorbing elements such as glass plates greater than 1/6of the combustion chamber surface, open water tanks, and so forth. It is also not valid for masonry heaters combined with heating/fireplace elements in accordance with EN 13229. Furthermore, this specification is not valid for mass-produced prefabricated or partly prefabricated slow heat release appliances according to EN 15250.
1.5The calculation method of this specification is used to establish emissions and energy efficiency when burning log wood or wood briquettes according to the manufacturer’s or builder’s manual.
1.6Clearance to Combustibles—When a masonry heater is constructed according to this specification, the clearance to combustibles shall be in accordance with TRVB 105 or other appropriate standards.
1.7Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ASTM E 1602 : 2003 : R2017 | Standard Guide for Construction of Solid Fuel Burning Masonry Heaters |
ASTM E 1602 : 2003 | Standard Guide for Construction of Solid Fuel Burning Masonry Heaters |
ASTM E 1602 : 2003 : R2010 : EDT 1 | Standard Guide for Construction of Solid Fuel Burning Masonry Heaters |
EN 15544:2009 | One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) - Dimensioning |
EN 13384-1:2015 | Chimneys - Thermal and fluid dynamic calculation methods - Part 1: Chimneys serving one heating appliance |
EN 15250:2007 | Slow heat release appliances fired by solid fuel - Requirements and test methods |
ASTM E 1602 : 2001 | Standard Guide for Construction of Solid Fuel Burning Masonry Heaters |
ASTM E 1602 : 1994 | Standard Guide for Construction of Solid Fuel Burning Masonry Heaters |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.