Standard Test Method for Resistance to Wildfire Penetration of Eaves, Soffits and Other Projections

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-06-2024

€56.53
Excluding VAT

Committee
E 05
DocumentType
Test Method
Pages
10
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

1.1This fire-test-response standard prescribes a method for qualitatively assessing the resistance to fire penetration of eave overhangs and other projections, such as the soffits of roof eaves and cantilevered floor projections, when exposed to direct flame impingement from a simulated external wildfire exposure, such as encountered in a “Wildland Urban Interface” scenario. This test method provides data suitable for comparing the relative performance of materials, which are used as the exposed underside surfaces of eave overhangs and other projections.

1.2This test method measures the ability of eave overhangs and other projections to resist fire penetration from the exterior into the wall cavity or unexposed side of the test specimen under the conditions of exposure.

1.3This test method is applicable to eave overhangs and other projections such as the soffits of roof eaves and cantilevered floor projections intended for use with either combustible or noncombustible building envelopes.

1.4Limitations of the test method are listed in Section 5.

1.5The values stated in metric units are to be regarded as the standard. Values in parentheses are for information only.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled laboratory conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.

1.8Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

1.9The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (including those in tables and figures) shall not be considered as requirements of the standard.

1.10This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E 176 : 2024 Standard Terminology of Fire Standards

ASTM C 1396/C1396M : 2017 Standard Specification for Gypsum Board
ASTM D 2898 : 2010 : R2024 Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
ASTM D 2898 : 2010 : R2017 Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing
ASTM C 1396/C1396M : 2024 Standard Specification for Gypsum Board

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.