ASTM E 2964 : 2014 : EDT 1
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Test Method for Measurement of the Normalized Insertion Loss of Doors
Hardcopy , PDF
01-05-2019
English
01-06-2014
CONTAINED IN VOL. 04.06, 2017 Gives a method of evaluating doors in such cases using a normalized insertion loss with a resulting single number rating door transmission class, DTC.
Committee |
E 33
|
DocumentType |
Test Method
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1The sound insulation properties of a door are measured in a laboratory as the sound transmission loss in accordance with Test Method E90. Using those data single number rating sound transmission class (STC) is assigned. In the field, the rooms on one or both sides of a partition containing a door are often either too small or too large and absorptive to allow the apparent transmission loss (ATL) of the partition-door assembly to be measured. Even if that is not the case, the result measured is the composite ATL of the partition including the door, and not that of the door itself. Test Method E336 actually states that it is impossible to measure the ATL of a portion of a partition such as a door according to the procedures of that standard. This test method provides a method of evaluating doors in such cases using a normalized insertion loss with a resulting single number rating door transmission class, DTC. This method is intended primarily for hinged personnel doors with latching mechanisms and is limited to door openings of area less than 6 m2. The flanking effects of surrounding structure are reduced compared to E336 but not completely eliminated. In a laboratory environment, the DTC is close to or equal to the STC of the door, but in the field results less than the laboratory STC should be expected.
1.2The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 1374 : 2018 : EDT 1 | Standard Guide for Office Acoustics and Applicable ASTM Standards |
ASTM E 3091 : 2017 | Standard Specification for Systems to Measure Sound Levels |
ASTM E 336 : 2019 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings |
ASTM E 966 : 2018 : REV A | Standard Guide for Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements |
ISO 16283-1:2014 | Acoustics Field measurement of sound insulation in buildings and of building elements Part 1: Airborne sound insulation |
ANSI S1.4 : 1983 | SPECIFICATION FOR SOUND LEVEL METERS |
ANSI S1.11 : 2014 | SPECIFICATION FOR OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND ANALOG AND DIGITAL FILTERS |
IEC 60942:2003 | Electroacoustics - Sound calibrators |
ANSI S1.10 : 66(R2001) | AMERICAN NATIONAL STANDARD METHOD FOR THE CALIBRATION OF MICROPHONES |
ASTM E 413 : 2016 : REDLINE | Classification for Rating Sound Insulation |
IEC 60804:2000 | Integrating-averaging sound level meters |