ASTM E 3069 : 2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Evaluation and Rehabilitation of Mass Masonry Walls for Changes to Thermal and Moisture Properties of the Wall
Hardcopy , PDF
07-03-2019
English
15-02-2017
CONTAINED IN VOL. 04.12, 2017 Specifies the evaluation of existing mass masonry walls for the potential addition of interior insulation and continuous air barrier or vapor retarder or other changes to the thermal and moisture management properties of the wall.
Committee |
E 06
|
DocumentType |
Guide
|
Pages |
7
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This guide addresses the evaluation of existing mass masonry walls for the potential addition of interior insulation and continuous air barrier or vapor retarder or other changes to the thermal and moisture management properties of the wall.
1.2This guide describes methods for evaluating causes of water infiltration or other moisture accumulation related problems specific to mass masonry walls. This guide does not apply to walls that include provisions to manage bulk water through internal drainage, flashings, or other measures other than the moisture storage capacity of the wall.
1.3This guide describes analysis, design, and specification of materials with the required thermal and vapor resistance to improve the energy performance of an existing mass masonry wall, but that would not create problematic conditions to the masonry units or within the masonry wall or interior of the building.
1.4This guide applies to walls of solid or multiwythe masonry construction meeting the requirements of a “mass masonry wall” as defined herein and having an overall thickness of solid masonry not less than 8 in. This guide does not apply to masonry walls that, by design, are intended to manage water as a barrier wall system or drainage wall system.
1.5The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ASHRAE 160 : 2009 | CRITERIA FOR MOISTURE-CONTROL DESIGN ANALYSIS IN BUILDINGS |
ICC IECC INTERNATIONAL ENERGY CONSERVATION CODE : 2015 | INTERNATIONAL ENERGY CONSERVATION CODE |
ASTM E 2128 : 2012 | Standard Guide for Evaluating Water Leakage of Building Walls |
ASTM C 1794 : 2015 | Standard Test Methods for Determination of the Water Absorption Coefficient by Partial Immersion |
ASTM E 398 : 2013 : REDLINE | Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.