• Shopping Cart
    There are no items in your cart

ASTM E 564 : 2006 : R2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Static Load Test for Shear Resistance of Framed Walls for Buildings

Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

01-10-2012

€67.30
Excluding VAT

CONTAINED IN VOL. 04.11, 2015 Describes methods for evaluating the shear capacity of a typical section of a framed wall, supported on a rigid foundation and having load applied in the plane of the wall along the edge opposite the rigid support and in a direction parallel to it.

Committee
E 06
DocumentType
Standard Practice
Pages
5
ProductNote
Reconfirmed 2012
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This practice describes methods for evaluating the shear capacity of a typical section of a framed wall, supported on a rigid foundation and having load applied in the plane of the wall along the edge opposite the rigid support and in a direction parallel to it. The objective is to provide a determination of the shear stiffness and strength of any structural light-frame wall configuration to be used as a shear-wall on a rigid support.

1.2Limitations—This practice is not intended to be used as a basis for classifying sheathing shear capacity or as an evaluation of combined flexure and shear resulting from the wall being loaded on a flexible foundation.

1.2.1The effect of sheathing variations is assessed by holding all other variables constant. Permitted variations in framing configuration and boundary conditions, however, require accurate documentation of the test setup to validate across-study comparisons of sheathing contribution to wall shear capacity.

Note 1A wall tested on a flexible foundation is evaluated by comparing shear stiffness and strength results to those of an identical wall tested on a rigid foundation, following this practice. However, no methods are given for the measurement of wall bending displacements or assessment of stress distribution resulting from foundation flexure. Any extrapolation of wall racking behavior from the foundation conditions specified by this practice to flexible conditions shall be done with the support of a comparative test on a representative foundation.

1.3The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E 631 : 2015 : REDLINE Standard Terminology of Building Constructions
ASTM E 122 : 2017 : REDLINE Standard Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process
ASTM E 72 : 2015 : REDLINE Standard Test Methods of Conducting Strength Tests of Panels for Building Construction

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.