ASTM E 576 : 2014 : REDLINE
Current
The latest, up-to-date edition.
Standard Test Method for Frost/Dew Point of Sealed Insulating Glass Units in the Vertical Position
English
01-12-2014
CONTAINED IN VOL. 04.11, 2016 Defines a field or laboratory procedure for determining the frost/dew point within the air space(s) of sealed insulating glass units and establishes the criteria for determining whether that point is below or above a given or specified temperature.
Committee |
E 06
|
DocumentType |
Redline
|
Pages |
14
|
PublisherName |
American Society for Testing and Materials
|
Status |
Current
|
1.1This test method describes a field or laboratory procedure for determining the frost/dew point within the air space(s) of sealed insulating glass units and establishes the criteria for determining whether that point is below or above a given or specified temperature.
1.2This test method also describes the apparatus to be used for these determinations.
1.3The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 9.1.3 and 9.3.8.
ASTM E 546 : 2014 : REDLINE | Standard Test Method for Frost/Dew Point of Sealed Insulating Glass Units |
ASTM E 2813 : 2012 | Standard Practice for Building Enclosure Commissioning |
ASTM E 2813 : 2012 : EDT 1 | Standard Practice for Building Enclosure Commissioning |
DD ISO/TR 15969:2001 | Surface chemical analysis. Depth profiling. Measurement of sputtered depth |
ISO/TR 15969:2001 | Surface chemical analysis Depth profiling Measurement of sputtered depth |
ASTM E 631 : 2015 : REDLINE | Standard Terminology of Building Constructions |
ASTM E 774 : 1997 | Standard Specification for the Classification of the Durability of Sealed Insulating Glass Units (Withdrawn 2006) |
ASTM C 1036 : 2016 : REDLINE | Standard Specification for Flat Glass |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.