CONTAINED IN VOL. 15.09, 2015 Defines a procedure for quantitating volatile compounds whose identity has been established and which are evolved when a microwave susceptor sample is tested under simulated use conditions.

Committee
F 02
DocumentType
Test Method
Pages
5
ProductNote
Reconfirmed 2008
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1 This test method covers complete microwave susceptors.

1.2 This test method covers a procedure for quantitating volatile compounds whose identity has been established and which are evolved when a microwave susceptor sample is tested under simulated use conditions.

1.3 This test method was collaboratively evaluated with a variety of volatile compounds (see statistical evaluation). For compounds other than those evaluated, the analyst should determine the sensitivity and reproducibility of the method by carrying out appropriate spike and recovery studies. The analyst is referred to Practice E 260 for guidance.

1.4 For purposes of verifying the identity of or identifying unknown volatile compounds, the analyst is encouraged to incorporate techniques such as gas chromatography/mass spectroscopy, gas chromatography/infrared spectroscopy, or other techniques in conjunction with this test method.

1.5 A sensitivity level of approximately 0.025 μg/in. is achievable for the compounds studied in Table 1. Where other compounds are being quantitated and uncertainty exists over method sensitivity, the analyst is referred to Practice E 260 for procedures on determining sensitivity of chromatographic methods.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific safety hazards warnings are given in 10.2, 11.1, and 11.6.

TABLE 1 Analyte Recovery Without Microwaving

Compound(n)ARecovery Mean, %Within Laboratory Variability, %Overall Variability, %Note(s)B
Benzene 5 97.7 7.8 9.0
2-Butoxy-ethanol4 98.7 6.7 8.41
Dibutyl Ether5109.716.5 23.7
Dodecane3101.110.7 10.71, 2
2-Furfural4 99.711.7 12.01
Furan-
2-Methanol
3 100.014.116.41, 3
Isobutyl Alcohol4 96.0 7.1 7.94
Methylene
Chloride
5 103.516.722.6
2-Propanol3 99.911.4 12.04
Styrene 5100.8 8.5 9.3
Toluene 4102.7 9.910.94
Overall101.1 11.614.4

A n = number of laboratories submitting data on compound.

B Notes: Collaborating laboratories provided the following reasons for not sub-
mitting data on a particular analyte:

1. The analyst felt interaction was occurring among various analytes and spent several days investigating. The laboratory manager refused to allow additional time for collaborative study.

2. The analyst questioned the solubility of the analyte and did not add to the spike mixture.

3. A fresh standard was not prepared fresh daily. This compound degrades measurably in water in 24 h.

4. The analyst experienced coelution of peaks under conditions of collaborative study on his/her particular system.

ASTM F 1317 : 1998 : R2019 Standard Test Method for Calibration of Microwave Ovens (Withdrawn 2024)
ASTM F 874 : 1998 : R2019 Standard Test Method for Temperature Measurement and Profiling for Microwave Susceptors (Withdrawn 2024)

ASTM E 260 : 1996 Standard Practice for Packed Column Gas Chromatography
ASTM F 1317 : 1998 Standard Test Method for Calibration of Microwave Ovens
TAPPI/ANSI T 402 sp:2013 STANDARD CONDITIONING AND TESTING ATMOSPHERES FOR PAPER, BOARD, PULP HANDSHEETS, AND RELATED PRODUCTS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.