CONTAINED IN VOL. 13.01, 2016 Defines rigid unicellular polyurethane foam for use as a standard material for performing mechanical tests utilizing orthopaedic devices or instruments.
Committee |
F 04
|
DocumentType |
Standard
|
Pages |
6
|
ProductNote |
Reconfirmed EDT 1
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This specification covers rigid unicellular polyurethane foam for use as a standard material for performing mechanical tests utilizing orthopaedic devices or instruments. The specification is applicable to sheets or blocks of foam, or foam that is made by the user using a two-part liquid mixture.
1.2This specification covers polyurethane foam material that is used in the laboratory for mechanical testing, as described in 1.1. These materials are not intended for implantation into the human body.
1.3The foam described herein possesses mechanical properties which are on the order of those reported for human cancellous bone. See Appendix X1, Rationale, for further information regarding the appropriateness of using the specified foam as a model for human cancellous bone.
1.4This specification covers compositional requirements, physical requirements, mechanical requirements, and test methods for rigid polyurethane foam in the solid final form.
1.5This specification provides qualification criteria for vendor or end-user processes and acceptance criteria for individual material lots.
1.6This specification provides mechanical properties of five different grades of foam in the solid final form. A foam that does not meet the specified mechanical properties shall be identified as an ungraded foam.
1.7The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8The following precautionary statement pertains to the test method portion only, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM F 543 : 2017 | Standard Specification and Test Methods for Metallic Medical Bone Screws |
ASTM F 2028 : 2017 | Standard Test Methods for Dynamic Evaluation of Glenoid Loosening or Disassociation |
ASTM F 2502 : 2017 | Standard Specification and Test Methods for Absorbable Plates and Screws for Internal Fixation Implants |
ASTM F 2267 : 2004 : R2018 | Standard Test Method for Measuring Load Induced Subsidence of Intervertebral Body Fusion Device Under Static Axial Compression |
ASTM F 2193 : 2018 : REV A | Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System |
ASTM D 1621 : 2016 : REDLINE | Standard Test Method for Compressive Properties of Rigid Cellular Plastics |
ASTM F 543 : 2017 : REDLINE | Standard Specification and Test Methods for Metallic Medical Bone Screws |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.