• Shopping Cart
    There are no items in your cart

ASTM F 1983 : 2014 : REDLINE

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications

Available format(s)

PDF

Superseded date

24-04-2023

Language(s)

English

Published date

02-02-2015

€67.30
Excluding VAT

CONTAINED IN VOL. 13.01, 2015 Gives experimental protocols for biological assays of tissue reactions to absorbable/resorbable biomaterials for implant applications.

Committee
F 04
DocumentType
Redline
Pages
6
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1This practice provides experimental protocols for biological assays of tissue reactions to absorbable biomaterials for implant applications. This practice applies only to absorbable materials with projected clinical applications in which the materials will reside in bone or soft tissue longer than 30 days and less than three years. Other standards with designated implantation times are available to address shorter time periods. Careful consideration should be given to the appropriateness of this practice for slowly degrading materials that will remain for longer than three years. It is anticipated that the tissue response to degrading biomaterials will be different from the response to nonabsorbable materials. In many cases, a chronic inflammatory response may be observed during the degradation phase, but the local histology should return to normal after absorption; therefore, the minimal tissue response usually equated with “biocompatibility” may require long implantations.

1.2The time period for implant absorption will vary depending on chemical composition implant size, implant location, and test subject species; therefore, the implantation times for examination of tissue response will be linked to the rate of absorption. No single implantation time is indicated in this practice.

1.3These protocols assess the effects of the material on the animal tissue in which it is implanted. The experimental protocols do not fully assess systemic toxicity, carcinogenicity, teratogenicity, or mutagenicity of the material. Other standards are available to address these issues.

1.4To maximize use of the animals in the study protocol, all toxicological findings should be recorded. There are some aspects of systemic toxicity, including effects of degradation products on the target organs, that can be addressed with this practice, and these effects should be documented fully.

1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM F 2150 : 2013 : REDLINE Standard Guide for Characterization and Testing of Biomaterial Scaffolds Used in Tissue-Engineered Medical Products
ASTM F 2721 : 2009 : R2014 Standard Guide for Pre-clinical <emph type="bdit">in vivo</emph> Evaluation in Critical Size Segmental Bone Defects
ASTM F 3089 : 2014 Standard Guide for Characterization and Standardization of Polymerizable Collagen-Based Products and Associated Collagen-Cell Interactions
BS EN ISO 10993-6:2016 Biological evaluation of medical devices Tests for local effects after implantation
I.S. EN ISO 10993-6:2016 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 6: TESTS FOR LOCAL EFFECTS AFTER IMPLANTATION (ISO 10993-6:2016)
ASTM F 2721 : 2009 Standard Guide for Pre-clinical <span class="bdit">in vivo</span> Evaluation in Critical Size Segmental Bone Defects
ANSI/AAMI/ISO 10993-6:2016 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 6: TESTS FOR LOCAL EFFECTS AFTER IMPLANTATION
ASTM F 2451 : 2005 : R2010 Standard Guide for <i>in vivo</i> Assessment of Implantable Devices Intended to Repair or Regenerate Articular Cartilage (Withdrawn 2019)
ASTM F 2883 : 2011 Standard Guide for Characterization of Ceramic and Mineral Based Scaffolds used for Tissue-Engineered Medical Products (TEMPs) and as Device for Surgical Implant Applications (Withdrawn 2020)
ASTM F 2451 : 2005 Standard Guide for <i>in vivo</i> Assessment of Implantable Devices Intended to Repair or Regenerate Articular Cartilage
14/30261590 DC : 0 BS EN ISO 10993-6 - BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 6: TESTS FOR LOCAL EFFECTS AFTER IMPLANTATION
EN ISO 10993-6:2016 Biological evaluation of medical devices - Part 6: Tests for local effects after implantation (ISO 10993-6:2016)
ASTM F 2884 : 2012 Standard Guide for Pre-clinical <emph type="bdit">in vivo</emph> Evaluation of Spinal Fusion (Withdrawn 2021)
ASTM F 748 : 2016 : REDLINE Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices
ASTM F 2212 : 2011 : REDLINE Standard Guide for Characterization of Type I Collagen as Starting Material for Surgical Implants and Substrates for Tissue Engineered Medical Products (TEMPs)
DIN EN ISO 10993-6:2009-08 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 6: TESTS FOR LOCAL EFFECTS AFTER IMPLANTATION (ISO 10993-6:2016)
ISO 10993-6:2016 Biological evaluation of medical devices Part 6: Tests for local effects after implantation
DIN EN ISO 10993-6:2017-09 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 6: TESTS FOR LOCAL EFFECTS AFTER IMPLANTATION (ISO 10993-6:2016)

ASTM F 561 : 2013 Standard Practice for Retrieval and Analysis of Medical Devices, and Associated Tissues and Fluids
ASTM F 1903 : 2010-07 PRACTICE FOR TESTING FOR BIOLOGICAL RESPONSES TO PARTICLES IN VITRO
ASTM F 1408 : 1997 Standard Practice for Subcutaneous Screening Test for Implant Materials
ASTM F 1904 : 2014 : REDLINE Standard Practice for Testing the Biological Responses to Particles <emph type="bdit" >in vivo</emph>

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.