ASTM F 2038 : 2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Guide for Silicone Elastomers, Gels and Foams Used in Medical Applications Part I - Formulations and Uncured Materials
Hardcopy , PDF
11-11-2014
English
10-06-2000
CONTAINED IN VOL. 13.01, 2015 Specifies the selection of appropriate materials, after consideration of the chemical, physical, and toxicological properties of individual ingredients or by-products.
Committee |
F 04
|
DocumentType |
Guide
|
Pages |
5
|
ProductNote |
Reconfirmed 2000
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This guide is intended to educate potential users of silicone elastomers, gels and foams relative to their formulation and use. It does not provide information relative to silicone powders, fluids, and other silicones. The information provided is offered to guide users in the selection of appropriate materials, after consideration of the chemical, physical and toxicological properties of individual ingredients or by-products. This standard offers general information about silicone materials typically used for medical applications. Detail on the crosslinking and fabrication of silicone materials is found in Part II of this standard.
1.2 Fabrication and properties of elastomers is covered in the companion document, F604, Part II. This monograph addresses only components of uncured elastomers, gels and foams.
1.3 Silicone biocompatibility issues can be addressed at several levels, but ultimately the device manufacturer must assess biological suitability relative to intended use.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Users are also advised to refer to Material Safety Data Sheets provided with uncured silicone components.
1.5 Biological and physical properties tend to be more reproducible when materials are manufactured in accordance with accepted quality standards such as ANSI ISO 9001 and current FDA Quality System Regulations/Good Manufacturing Practice Regulations.
ASTM F 1781 : 2015 | Standard Specification for Elastomeric Flexible Hinge Finger Total Joint Implants |
ASTM F 1441 : 2003 : R2014 | Standard Specification for Soft-Tissue Expander Devices |
ASTM F 2042 : 2018 | Standard Guide for Silicone Elastomers, Gels, and Foams Used in Medical Applications Part II—Crosslinking and Fabrication |
ASTM F 703 : 2018 | Standard Specification for Implantable Breast Prostheses |
AAMI ST41 : 2008 | ETHYLENE OXIDE STERILIZATION IN HEALTH CARE FACILITIES: SAFETY AND EFFECTIVENESS |
CFR 21(PTS200-299) : 0 | FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 200-299 |
AAMI ST30 : 1989 | DETERMINING RESIDUAL ETHYLENE CHLOROHYDRIN AND ETHYLENE GLYCOL IN MEDICAL DEVICES |
CFR 21(PTS800-1299) : 0 | FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299 |
AAMI ST29 : 1988 | DETERMINING RESIDUAL ETHYLENE OXIDE IN MEDICAL DEVICES |
ANSI/ISO/ASQ Q9001:2008 | Quality Management Systems - Requirements |
ASTM D 1566 : 2015 : REDLINE | TERMINOLOGY RELATING TO RUBBER |
AAMI TIR 8 : 1ED 91 | MICROBIOLOGICAL METHODS FOR GAMMA IRRADIATION STERILIZATION OF MEDICAL DEVICES |
AAMI ISO TIR 13409 : 1996 ERRATA 2005 | STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION STERILIZATION - SUBSTANTIATION OF 25 KGY AS A STERILIZATION DOSE FOR SMALL OR INFREQUENT PRODUCTION BATCHES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.