Standard Test Method for Measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment
Hardcopy , PDF
21-01-2022
English
23-09-2015
This test method covers the measurement of the magnetically induced displacement force produced by static magnetic field gradients on medical devices and the comparison of that force to the weight of the medical device.
Committee |
F 04
|
DocumentType |
Test Method
|
Pages |
7
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This test method covers the measurement of the magnetically induced displacement force produced by static magnetic field gradients on medical devices and the comparison of that force to the weight of the medical device.
1.2This test method does not address other possible safety issues which include but are not limited to issues of magnetically induced torque, RF heating, induced heating, acoustic noise, interaction among devices, and the functionality of the device and the MR system.
1.3This test method is intended for devices that can be suspended from a string. Devices which cannot be suspended from a string are not covered by this test method. The weight of the string from which the device is suspended during the test must be less than 1 % of the weight of the tested device.
1.4This test method shall be carried out in a horizontal bore MR system with a static magnetic filed oriented horizontally and parallel to the MR system bore.
1.5The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
ASTM F 3160 : 2016 | Standard Guide for Metallurgical Characterization of Absorbable Metallic Materials for Medical Implants |
ASTM F 1831 : 2017 | Standard Specification for Cranial Traction Tongs and Halo External Spinal Immobilization Devices |
ASTM F 3160 : 2021 | Standard Guide for Metallurgical Characterization of Absorbable Metallic Materials for Medical Implants |
ASTM F 2119 : 2007 : R2013 | Standard Test Method for Evaluation of MR Image Artifacts from Passive Implants (Withdrawn 2022) |
ASTM F 2182 : 2011 : REV A | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2213 : 2017 | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ASTM F 2503 : 2013 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 2503 : 2008 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 2213 : 2002 | Standard Test Method for Measurement of Magnetically Induced Torque on Passive Implants in the Magnetic Resonance Environment |
ASTM F 2182 : 2002 | Standard Test Method for Measurement of Radio Frequency Induced Heating Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2213 : 2006 : R2011 | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ASTM F 2503 : 2005 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 2213 : 2006 | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ASTM F 2182 : 2019 : EDT 1 | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2182 : 2019 : EDT 2 | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2119 : 2007 | Standard Test Method for Evaluation of MR Image Artifacts from Passive Implants |
ASTM F 2503 : 2013 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 2182 : 2019 | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2119 : 2001 | Standard Test Method for Evaluation of MR Image Artifacts from Passive Implants |
ASTM F 2503 : 2020 | Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment |
ASTM F 2213 : 2004 | Standard Test Method for Measurement of Magnetically Induced Torque on Passive Implants in the Magnetic Resonance Environment |
ASTM F 2119 : 2007 : R2013 | Standard Test Method for Evaluation of MR Image Artifacts from Passive Implants (Withdrawn 2022) |
ASTM F 2182 : 2009 | Standard Test Method for Measurement of Radio Frequency Induced Heating Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2213 : 2017 | Standard Test Method for Measurement of Magnetically Induced Torque on Medical Devices in the Magnetic Resonance Environment |
ASTM F 2182 : 2011 : REV A | Standard Test Method for Measurement of Radio Frequency Induced Heating On or Near Passive Implants During Magnetic Resonance Imaging |
ASTM F 2182 : 2002 : REV A | Standard Test Method for Measurement of Radio Frequency Induced Heating Near Passive Implants During Magnetic Resonance Imaging |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.