Standard Guide for Characterization of Type I Collagen as Starting Material for Surgical Implants and Substrates for Tissue Engineered Medical Products (TEMPs)
28-01-2021
English
01-04-2011
CONTAINED IN VOL. 13.01, 2015 Gives characteristics, properties and test methods for use by producers, manufacturers and researchers to more clearly identify the specific collagen materials used.
Committee |
F 04
|
DocumentType |
Redline
|
Pages |
15
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1 This guide for characterizing collagen-containing biomaterials is intended to provide characteristics, properties, and test methods for use by producers, manufacturers, and researchers to more clearly identify the specific collagen materials used. With greater than 20 types of collagen and the different properties of each, a single document would be cumbersome. This guide will focus on the characterization of Type I collagen, which is the most abundant collagen in mammals, especially in skin and bone. Collagen isolated from these sources may contain other types of collagen, for example, Type III and Type V. This guide does not provide specific parameters for any collagen product or mix of products or the acceptability of those products for the intended use. The collagen may be from any source, including, but not limited to, animal or cadaveric sources, human cell culture, or recombinant sources. The biological, immunological, or toxicological properties of the collagen may vary, depending on the source material. The properties of the collagen prepared from each of the above sources must be thoroughly investigated, as the changes in the collagen properties as a function of source materials is not thoroughly understood. This guide is intended to focus on purified Type I collagen as a starting material for surgical implants and substrates for tissue engineered medical products (TEMPs); some methods may not be applicable for gelatin or tissue implants. This guide may serve as a template for characterization of other types of collagen.
1.2 The biological response to collagen in soft tissue has been well documented by a history of clinical use (1, 2) and laboratory studies (3, 4, 5, 6). Biocompatibility and appropriateness of use for a specific application(s) is the responsibility of the product manufacturer.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 Warning
1.5 The following precautionary caveat pertains only to the test method portion, Section 5, of this guide. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
ASTM F 3225 : 2017 | Standard Guide for Characterization and Assessment of Vascular Graft Tissue Engineered Medical Products (TEMPs) |
ASTM F 2027 : 2016 : REDLINE | Standard Guide for Characterization and Testing of Raw or Starting Materials for Tissue-Engineered Medical Products |
ASTM F 2150 : 2013 : REDLINE | Standard Guide for Characterization and Testing of Biomaterial Scaffolds Used in Tissue-Engineered Medical Products |
ISO 13019:2018 | Tissue-engineered medical products — Quantification of sulfated glycosaminoglycans (sGAG) for evaluation of chondrogenesis |
ISO 16142-1:2016 | Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards |
17/30319534 DC : 0 | BS ISO 13019 - TISSUE-ENGINEERED MEDICAL PRODUCTS - QUANTIFICATION OF SULPHATED GLYCOSAMINOGLYCANS (SGAG) FOR EVALUATION OF CHONDROGENESIS |
14/30290166 DC : 0 | BS ISO 16142-1 - MEDICAL DEVICES - RECOGNIZED ESSENTIAL PRINCIPLES OF SAFETY AND PERFORMANCE OF MEDICAL DEVICES - PART 1: GENERAL ESSENTIAL PRINCIPLES AND ADDITIONAL SPECIFIC ESSENTIAL PRINCIPLES FOR ALL NON-IVD MEDICAL DEVICES AND GUIDANCE ON THE SELECTION OF STANDARDS |
BS ISO 16142-1:2016 | Medical devices. Recognized essential principles of safety and performance of medical devices General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards |
ASTM F 2903 : 2011 | Standard Guide for Tissue Engineered Medical Products (TEMPs) for Reinforcement of Tendon and Ligament Surgical Repair (Withdrawn 2020) |
ASTM F 3223 : 2017 | Standard Guide for Characterization and Assessment of Tissue Engineered Medical Products (TEMPs) for Knee Meniscus Surgical Repair and/or Reconstruction |
EN 12442-3 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 3: VALIDATION OF THE ELIMINATION AND/OR INACTIVATION OF VIRUSES AND TRANSMISSIBLE AGENTS |
AAMI TIR19 : 1998 | GUIDANCE FOR ANSI/AAMI/ISO 10993-7: 1995, BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 7: ETHYLENE OXIDE STERILIZATION RESIDUALS |
ISO 10993-3:2014 | Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity |
ASTM F 756 : 2017 : REDLINE | Standard Practice for Assessment of Hemolytic Properties of Materials |
CFR 21(PTS200-299) : 0 | FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 200-299 |
ASTM F 1983 : 2014 : REDLINE | Standard Practice for Assessment of Selected Tissue Effects of Absorbable Biomaterials for Implant Applications |
CFR 21(PTS800-1299) : 0 | FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299 |
ASTM F 749 : 2013 : REDLINE | Standard Practice for Evaluating Material Extracts by Intracutaneous Injection in the Rabbit |
ASTM F 1903 : 2010-07 | PRACTICE FOR TESTING FOR BIOLOGICAL RESPONSES TO PARTICLES IN VITRO |
ISO 10993-10:2010 | Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization |
ISO 13408-1:2008 | Aseptic processing of health care products — Part 1: General requirements |
ASTM F 619 : 2014 : REDLINE | Standard Practice for Extraction of Medical Plastics |
CFR 21(PTS300-499) : 0 | FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 300-499 |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ASTM F 748 : 2016 : REDLINE | Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices |
ASTM F 720 : 2017 : REDLINE | Standard Practice for Testing Guinea Pigs for Contact Allergens: Guinea Pig Maximization Test |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ASTM F 1904 : 2014 : REDLINE | Standard Practice for Testing the Biological Responses to Particles <emph type="bdit" >in vivo</emph> |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
EN 12442-1 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 1: ANALYSIS AND MANAGEMENT OF RISK |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
EN 12442-2 : 2000 | ANIMAL TISSUES AND THEIR DERIVATIVES UTILIZED IN THE MANUFACTURE OF MEDICAL DEVICES - PART 2: CONTROLS ON SOURCING, COLLECTION AND HANDLING |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.