• ASTM F 2319 : 2004

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Standard Specification for Fixed Wing Basic Life Support, Advanced Life Support, and Specialized Medical Support Air Ambulances (Withdrawn 2013)

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  31-07-2013

    Language(s):  English

    Published date:  01-04-2004

    Publisher:  American Society for Testing and Materials

    Add To Cart

    Abstract - (Show below) - (Hide below)

    CONTAINED IN VOL. 13.02, 2012 Describes the minimum requirements, including personnel, and patient care equipment and supplies, that must be met before the aircraft can be classified as a fixed wing air ambulance unit.

    Scope - (Show below) - (Hide below)

    1.1 This specification pertains to fixed wing aircraft (airplanes) used for patient prehospital emergency medical care and transportation. It outlines the minimum requirements, including personnel, and patient care equipment and supplies, that must be met before the aircraft can be classified as a fixed wing air ambulance unit.

    1.2 The first part of this specification (Sections through ) describes the minimum aircraft configuration and capability, the minimum number of seats for personnel, and the provisions for the minimum medical equipment and supplies for fixed wing basic life support air ambulances.

    1.3 The provisions of this specification plus the provisions of the Advanced Life Support (ALS) Annex comprise the specification for fixed wing advanced life support air ambulances. See Sections 1 and 1.1 of the Advanced Life Support (ALS) Annex for the scope for fixed wing advanced life support air ambulances.

    1.4 The provisions of this Sspecification plus the provisions of the Advanced Life Support Annex, plus the provisions in this Specialized Medical Support (SMS) Annex comprise the specification for fixed wing specialized medical support air ambulances. See Sections 1 through 1.3 of the Specialized Medical Support (SMS) Annex for the scope for fixed wing specialized medical support air ambulances.

    General Product Information - (Show below) - (Hide below)

    Committee F 30
    Document Type Standard
    Publisher American Society for Testing and Materials
    Status Withdrawn

    Standards Referencing This Book - (Show below) - (Hide below)

    CSA Z305.3 : 0 PRESSURE REGULATORS, GAUGES AND FLOW-METERING DEVICES FOR MEDICAL GASES
    SAE AIR 825 : 2012 OXYGEN EQUIPMENT FOR AIRCRAFT
    CGA V 1 : 2013 STANDARD FOR COMPRESSED GAS CYLINDER VALVE OUTLET AND INLET CONNECTIONS
    MIL-STD-704 Revision F:2004 AIRCRAFT ELECTRIC POWER CHARACTERISTICS
    MIL-STD-101 Revision C:2014 COLOR CODE FOR PIPELINES AND FOR COMPRESSED GAS CYLINDERS
    CFR 29(PTS900-1899) : 2017 LABOR - DEPARTMENT OF LABOR
    CFR 29(PTS1900-1910) : 0 LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
    MIL-STD-810 Revision G:2008 ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS
    ANSI Z79.3 : 1983 OROPHARYNGEAL AND NASOPHARYNGEAL AIRWAYS,
    SAE AS 1198 : 1995 AEROSPACE WIRE AND CABLES, METHODS OF TESTING
    ASTM F 960 : 1986 SPECIFICATION FOR MEDICAL AND SURGICAL SUCTION AND DRAINAGE SYSTEMS
    ASTM F 1219 : 2000 Standard Guide for Training the Emergency Medical Technician (Basic) to Perform Patient Initial and Detailed Assessment (Withdrawn 2006)
    CGA C 9 : 2013 STANDARD COLOR MARKING OF COMPRESSED GAS CONTAINERS FOR MEDICAL USE
    ASTM F 1031 : 2013 : REDLINE Standard Practice for Training the Emergency Medical Technician (Basic) (Withdrawn 2022)
    MIL-STD-461 Revision G:2015 REQUIREMENTS FOR THE CONTROL OF ELECTROMAGNETIC INTERFERENCE CHARACTERISTICS OF SUBSYSTEMS AND EQUIPMENT
    ASTM F 920 : 1993 : R1999 Standard Specification for Minimum Performance and Safety Requirements for Resuscitators Intended for Use With Humans (Withdrawn 2007)
    NFPA 99 : 2018 HEALTH CARE FACILITIES CODE
    NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
    NFPA 56 : 2017 FIRE AND EXPLOSION PREVENTION DURING CLEANING AND PURGING OF FLAMMABLE GAS PIPING SYSTEMS
    CGA V 5 : 2008(R2013) DIAMETER INDEX SAFETY SYSTEM (NON-INTERCHANGEABLE LOW PRESSURE CONNECTIONS FOR MEDICAL GAS APPLICATIONS)
    MIL-STD-1472 Revision G:2012 HUMAN ENGINEERING
    ANSI Z79.14 : 1983 TRACHEAL TUBES,
    MIL-STD-202 Revision H:2015 ELECTRONIC AND ELECTRICAL COMPONENT PARTS
    CGA P2 : 0 TESTING METHOD FOR MEASURING ANNUAL FUEL UTILIZATION EFFICIENCIES OF RESIDENTIAL FURNACES AND BOILERS
    CGA E 7 : 2013 MEDICAL GAS PRESSURE REGULATORS, FLOWMETERS, AND ORIFICE FLOW SELECTORS
    CSA Z305.1 : 0 NONFLAMMABLE MEDICAL GAS PIPING SYSTEMS
    NFPA 407 : 2017 AIRCRAFT FUEL SERVICING
    ANSI Z79.6 : 1975 BREATHING TUBES,
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective