• Shopping Cart
    There are no items in your cart

ASTM F 773 : 1992

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Practice for Measuring Dose Rate Response of Linear Integrated Circuits

Withdrawn date

11-11-2014

Superseded by

ASTM F 773M : 1996

Published date

01-01-1992

Sorry this product is not available in your region.

CONTAINED IN VOL 10.04 Covers measurement of the response of linear integrated circuits, to pulsed ionizing radiation.

Committee
F 01
DocumentType
Standard Practice
PublisherName
American Society for Testing and Materials
Status
Withdrawn
SupersededBy

1.1 This practice covers the measurement of the response of linear integrated circuits, under given operating conditions, to pulsed ionizing radiation. The response may be either transient or more lasting, such as latchup. The radiation source is either a flash X-ray machine (FXR) or an electron linear accelerator (LINAC).

1.2 The precision of the measurement depends on the homogeneity of the radiation field and on the precision of the radiation dosimetry and the recording instrumentation.

1.3 The test may be considered to be destructive either for further tests or for other purposes if the total radiation dose exceeds some predetermined level. Because this level depends both on the kind of integrated circuit and on the application, a specific value must be agreed upon by the parties to the test. (See 6.10.)

1.4 Setup, calibration, and test circuit evaluation procedures are included in this practice.

1.5 Procedures for lot qualification and sampling are not included in this practice.

1.6 Because response varies with different device types, the dose rate range for any specific test is not given in this practice but must be agreed upon by the parties to the test.

1.7 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statement is given in 7.9.2.

MIL-HDBK-817 Base Document:1994 SYSTEM DEVELOPMENT RADIATION HARDNESS ASSURANCE
MIL-HDBK-815 Base Document:1994 DOSE-RATE HARDNESS ASSURANCE GUIDELINES

ASTM F 526 : 2016 : REDLINE Standard Test Method for Using Calorimeters for Total Dose Measurements in Pulsed Linear Accelerator or Flash X-ray Machines
ASTM E 668 : 2013 : REDLINE Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.