BS 2000-71-2:1995
Current
The latest, up-to-date edition.
Methods of test for petroleum and its products. Kinematic viscosity Specifications and operating instructions for glass capillary kinematic viscometers
Hardcopy , PDF
English
31-03-1995
Identical with IP 71 Section 2/95.
Committee |
PTI/13
|
DocumentType |
Standard
|
Pages |
56
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard gives specifications and operating instructions for glass capillary viscometers widely used for the determination of kinematic viscosity of petroleum products by the procedure described in ISO 3104. The calibration of these viscometers is also described.
The types of viscometers described are modified Ostwald viscometers (annex A), suspended-level viscometers (annex B) and reverse-flow viscometers (annex C). Other viscometers of the glass capillary type which are capable of measuring kinematic viscosity within the limits of precision given in ISO 3104 may be used.