• There are no items in your cart

BS 3G 231:1997

Current

Current

The latest, up-to-date edition.

Specification for conductors for general-purpose aircraft electrical cables and aerospace applications

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-01-1997

Foreword
Specification
1 Scope
2 Informative references
3 Materials
4 Construction
5 Electrical resistance after insulation
6 Tests
7 Packaging and labelling
Annex
A (normative) Corresponding mass per unit length of
    silver for a nominal 1 mn radial thickness
Tables
1 Conductor material
2 Concentric stranded conductors prior to insulation
3 Rope stranded conductors prior to insulation
4 Electrical resistance of concentric stranded
    conductors after insulation
5 Tensile strength and elongation at break of
    conductor prior to insulation
6 Tensile strength and elongation at break of
    conductor after insulation
A.1 Corresponding mass per unit length of silver for a
    nominal 1 mn radial thickness
List of references

Defines dimensions and performance requirements for multi-strand circular conductors in two conditions, ie prior to application of insulation and after insulation, as processing during manufacture of cable could change the characteristics of the conductor.

Committee
ACE/6
DevelopmentNote
Supersedes 96/703766 DC and BS 2G231(1990) (07/2005) Reviewed and confirmed by BSI, December 2009. (11/2009)
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Current
Supersedes

This British Standard specifies dimensions and performance requirements for multi-strand circular conductors in two distinct conditions:

  1. prior to application of insulation; and
  2. after insulation, since processing during cable manufacture may change the conductor characteristics.

The conductors specified in this standard are for general-purpose aircraft electrical cables for aerospace applications over the nominal cross-sectional area range 0.1 mm2 to 107 mm2.

NOTE. This standard does not apply to conductors for fire-resistant cables, thermocouple extension cables or equipment wire.

DEFSTAN 00-970(PT1)SEC6/10(2013) : 2013 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT
DEFSTAN 00-970(PT1)SEC6/9(2012) : 2012 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6 - EQUIPMENT
DEFSTAN 61-12(PT0)/3(2011) : 2011 WIRES, CORDS AND CABLES ELECTRICAL METRIC UNITS - PART 0: GENERAL REQUIREMENTS AND TEST METHODS GENERIC SPECIFICATION
DEFSTAN 00-970(PT7)SEC7/1(2006) : 2006 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 7: ROTORCRAFT - SECTION 7: INSTALLATIONS
DEFSTAN 00-970(PT1)SEC6/12(2014) : 2014 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT
DEFSTAN 61-12(PT18)/5(2006) : 2006 WIRES, CORDS AND CABLES, ELECTRICAL - PART 18: EQUIPMENT WIRES LIMITED FIRE HAZARD
DEFSTAN 00-970(PT1)SEC6/11(2013) : 2013 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT
DEFSTAN 61-12(PT0)/2(2006) : 2006 WIRES, CORDS AND CABLES, ELECTRICAL - PART 0: GENERAL REQUIREMENTS AND TEST METHODS - GENERAL SPECIFICATION
DEFSTAN 00-970(PT7)SEC7/2(2007) : 2007 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 7: ROTORCRAFT - SECTION 7: INSTALLATIONS
DEFSTAN 61-12(PT26)/3(2001) : 2001 WIRES, CORDS AND CABLES, ELECTRICAL - PART 26: WIRES AND CABLES ELECTRICAL, DUAL EXTRUDED INSULATION TYPE OLEFIN/VINYLIDEN-FLUORIDE AND SCREENED AND JACKETED - SECTIONAL SPECIFICATION
DEFSTAN 00-970(PT1)SEC6/8(2011) : 2011 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6 - EQUIPMENT
DEFSTAN 00-970(PT7)SEC7/3(2010) : 2010 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 7: ROTORCRAFT - SECTION 7: INSTALLATIONS
DEFSTAN 00-970(PT1)SEC6/6(2010) : 2010 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT
BS 3G 230:2000 Specification for general requirements for aircraft electrical cables (second series)
BS ISO 2635 : 2003 AIRCRAFT - CONDUCTORS FOR GENERAL PURPOSE AIRCRAFT ELECTRICAL CABLES AND AEROSPACE APPLICATIONS - DIMENSIONS AND CHARACTERISTICS
DEFSTAN 61-12(PT33)/3(2000) : 2000 WIRES, CORDS AND CABLES, ELECTRICAL PART 33: AIRFRAME WIRES AND CABLES IN THE TEMPERATURE CATEGORIES OF 135 DEGREE CENTIGRADE, 150 DEGREE CENTIGRADE, 200 DEGREE CENTIGRADE AND 260 DEGREE CENTIGRADE SECTIONAL SPECIFICATION
DEFSTAN 00-970(PT1)SEC6/5(2007) : 2007 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: COMBAT AIRCRAFT - SECTION 6: EQUIPMENT
ISO 2635:2003 Aircraft Conductors for general purpose aircraft electrical cables and aerospace applications Dimensions and characteristics
DEFSTAN 00-970(PT1)SEC6/7(2011) : 2011 DESIGN AND AIRWORTHINESS REQUIREMENTS FOR SERVICE AIRCRAFT - PART 1: FIXED WING - SECTION 6: EQUIPMENT

ISO 2635:2003 Aircraft Conductors for general purpose aircraft electrical cables and aerospace applications Dimensions and characteristics
BS G 222:1976 Specification for Efglas type electric cables (metric units)

€140.23
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.