Foreword
1 Scope
2 Definitions
3 Apparatus
4 Ancillary equipment
5 Specimen preparation and construction
6 Setting up procedure
7 Test procedure
8 Expression of results
9 Report
Appendix A - Summary test report
Publications referred to
This method measures air leakage of door and shutter assemblies under ambient temperature conditions as being representative of smoke penetration occurring from the early stages or at a remote position from a fire occurring in a building.
Committee |
FSH/22
|
DevelopmentNote |
Supersedes 80/11208 DC and 94/303067 DC. (06/2004)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This Section of this British Standard describes a method for measuring smoke penetration, as represented by the measurement of air leakage rate, through doorsets and vertically oriented shutter assemblies under ambient temperature conditions. This method is used to evaluate the performance of a fire door used for smoke control purposes but gives no information on the fire resistance of a fire door for which the methods described in BS 476-22 are applicable.
NOTE The titles of the publications referred to in this standard are listed on the inside back cover.
12/30263295 DC : 0 | BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION |
BS 5588-11:1997 | Fire precautions in the design, construction and use of buildings Code of practice for shops, offices, industrial, storage and other similar buildings |
16/30332500 DC : 0 | BS 8214 - TIMBER-BASED FIRE DOOR ASSEMBLIES - CODE OF PRACTICE |
BS 8524-1:2013 | Active fire curtain barrier assemblies Specification |
BS 5588-1:1990 | Fire precautions in the design, construction and use of buildings Code of practice for residential buildings |
BS 5588-10:1991 | Fire precautions in the design, construction and use of buildings Code of practice for shopping complexes |
BS 8214:2016 | Timber-based fire door assemblies. Code of practice |
BS 8214:2008 | Code of practice for fire door assemblies |
BS 5588-6:1991 | Fire precautions in the design, construction and use of buildings Code of practice for places of assembly |
BS PAS 121(2007) : 2007 | SPECIFICATION FOR ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES AND ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WITH SMOKE RATING |
BS 5588-2:1985 | Fire precautions in the design, construction and use of buildings Code of practice for shops |
BS 5588-7:1997 | Fire precautions in the design, construction and use of buildings Code of practice for the incorporation of atria in buildings |
BS 5588-8:1999 | Fire precautions in the design, construction and use of buildings Code of practice for means of escape for disabled people |
BS 6510:2010 | Steel-framed windows and glazed doors. Specification |
PD 7974-3:2011 | Application of fire safety engineering principles to the design of buildings Structural response and fire spread beyond the enclosure of origin |
BS 5588-5:1991 | Fire precautions in the design, construction and use of buildings Code of practice for firefighting stairs and lifts |
BS 6510:2005 | Steel-framed windows and glazed doors |
BS 476-10:2009 | Fire tests on building materials and structures Guide to the principles, selection, role and application of fire testing and their outputs |
BS 8524-2:2013 | Active fire curtain barrier assemblies Code of practice for application, installation and maintenance |
09/30189801 DC : 0 | BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION |
07/30147204 DC : 0 | BS 476-10 - FIRE TESTS ON BUILDING MATERIALS AND STRUCTURES - PART 10: GUIDE TO THE PRINCIPLES, SELECTION, ROLE AND APPLICATION OF FIRE TESTING AND THEIR OUTPUTS |
BS 5588-5:1986 | Fire precautions in the design and construction of buildings. Code of practice for firefighting stairways and lifts |
PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
BS 5588-8:1988 | Fire precautions in the design, construction and use of buildings Code of practice for means of escape for disabled people |
12/30205676 DC : 0 | BS 8524-2 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 2: CODE OF PRACTICE |
PD 6520:1988 | Guide to fire test methods for building materials and elements of construction |
BS 8214:1990 | Code of practice for fire door assemblies with non-metallic leaves |
04/30100932 DC : DRAFT AUG 2004 | BS 6510 - STEEL-FRAMED WINDOWS AND GLAZED DOORS |
BS 5588-3:1983 | Fire precautions in the design, construction and use of buildings Code of practice for office buildings |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
ISO 5925-1:2007 | Fire tests — Smoke-control door and shutter assemblies — Part 1: Ambient- and medium-temperature leakage tests |
BS 4422:2005 | Fire. Vocabulary |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.