• BS PAS 121(2007) : 2007

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    SPECIFICATION FOR ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES AND ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WITH SMOKE RATING

    Available format(s):  Hardcopy, PDF

    Withdrawn date:  01-07-2013

    Language(s):  English

    Published date:  01-01-2007

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    0 Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Product requirements
    5 Performance requirements and classifications
    6 Installation information
    7 Maintenance information
    8 Marking and labelling
    Annexes
    Annex A (informative) - Building management
    Annex B (normative) - General testing requirements
    Annex C (normative) - Test method for reliability and
            response time of the product and the durability
            of materials
    Annex D (normative) - Test method for the determination
            of the fire resistance performance of fire curtain
            barrier assemblies
    Annex E (informative) - An engineered approach to using
            insulating zones
    Annex F (informative) - Thermal limits - Human factors
    Bibliography

    Abstract - (Show below) - (Hide below)

    Provides requirements for design, specification, testing, installation, commissioning and maintenance of active fire curtain barrier assemblies.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher British Standards Institution
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    12/30263295 DC : 0 BS 8524-1 - ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES - PART 1: SPECIFICATION
    BS 8524-1:2013 Active fire curtain barrier assemblies Specification
    BS 9991:2011 Fire safety in the design, management and use of residential buildings. Code of practice
    BS 8524-2:2013 Active fire curtain barrier assemblies Code of practice for application, installation and maintenance

    Standards Referencing This Book - (Show below) - (Hide below)

    BS EN 13501-2 : 2007 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 2: CLASSIFICATION USING DATA FROM FIRE RESISTANCE TESTS, EXCLUDING VENTILATION SERVICES
    BS EN 1634-1 : 2014 FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 1: FIRE RESISTANCE TEST FOR DOOR AND SHUTTER ASSEMBLIES AND OPENABLE WINDOWS
    BS EN 1364-2:1999 Fire resistance tests for non-loadbearing elements Ceilings
    BS EN 50200:2015 Method of test for resistance to fire of unprotected small cables for use in emergency circuits
    BS EN ISO 13943:2017 Fire safety. Vocabulary
    BS EN 1634-3:2004 Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware Smoke control test for door and shutter assemblies
    BS 5588-12:2004 Fire precautions in the design, construction and use of buildings Managing fire safety
    BS EN 14600:2005 Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification
    BS EN 1364-1:2015 Fire resistance tests for non-loadbearing elements Walls
    BS 8434-2(2003) : 2003 METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY
    BS EN 1363-2:1999 Fire resistance tests Alternative and additional procedures
    BS 476-20:1987 Fire tests on building materials and structures Method for determination of the fire resistance of elements of construction (general principles)
    BS EN 949:1999 Windows and curtain walling, doors, blinds and shutters. Determination of the resistance to soft and heavy body impact for doors
    BS EN 1363-1:2012 Fire resistance tests General requirements
    BS 8434-1:2003 Methods of test for assessment of the fire integrity of electric cables Test for unprotected small cables for use in emergency circuits. BS EN 50200 with addition of water spray
    BS EN 12101-1 : 2006 SMOKE AND HEAT CONTROL SYSTEMS - PART 1: SPECIFICATION FOR SMOKE BARRIERS
    BS 7346-6:2005 Components for smoke and heat control systems Specifications for cable systems
    EN 15269-1:2010 Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 1: General requirements
    PD 7974-6:2004 The application of fire safety engineering principles to fire safety design of buildings Human factors. Life safety strategies. Occupant evacuation, behaviour and condition (Sub-system 6)
    ISO/IEC Guide 2:2004 Standardization and related activities General vocabulary
    BS 7974:2001 Application of fire safety engineering principles to the design of buildings. Code of practice
    BS 476-31.1:1983 Fire tests on building materials and structures Methods for measuring smoke penetration through doorsets and shutter assemblies - Method of measurement under ambient temperature conditions
    BS EN 12101-10:2005 Smoke and heat control systems Power supplies
    BS 476-22:1987 Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction