• BS 5440-1:2008

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Flueing and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases) Specification for installation of gas appliances to chimneys and for maintenance of chimneys

    Available format(s): 

    Superseded date:  12-12-2023

    Language(s): 

    Published date:  31-03-2008

    Publisher:  British Standards Institution

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Competence
    5 General
       5.1 Compatibility of appliances and chimneys
       5.2 Chimney outlets
       5.3 Chimneys for use with condensing appliances (open-flued
            and room-sealed)
       5.4 Location of appliances
       5.5 Passive stack ventilation
       5.6 Exchange of information and planning
       5.7 Maintenance
    6 Individual open-flued natural draught Types B[11], B[12], B[13]
       appliances
       6.1 Design
       6.2 Installation
       6.3 Commissioning
       6.4 Radon gas systems present
       6.5 Maintenance
    7 Individual open-flued fanned draught Types B[14], B[22], B[23]
       appliances and fanned draught chimneys
       7.1 Design
       7.2 Installation
       7.3 Commissioning
       7.4 Maintenance
    8 Shared open flue chimney for natural draught Types B[11], B[12],
       B[13] appliances
       8.1 Design
       8.2 Installation
       8.3 Maintenance
    9 Room-sealed natural draught chimney configurations (balanced flue)
       for Type C[11] appliances
       9.1 General
       9.2 Installation
       9.3 Installation checks
       9.4 Maintenance
    10 Room-sealed: fanned draught chimney configurations balanced flue
       (Type C[12], C[13], C[32] and C[33]) and non-balanced flue (Type
       C[52], C[53], C[62] and C[63]) appliances
       10.1 Design options
       10.2 Installation
       10.3 Installation checks
       10.4 Maintenance
    11 Balanced compartment
       11.1 General
       11.2 Design
       11.3 Balanced compartment construction
       11.4 Temperature effects
       11.5 Terminals
       11.6 Commissioning
       11.7 Maintenance
    12 Room-sealed Types C[2] and C[4] appliances for shared chimneys
       12.1 Selection and installation of a suitable chimney
       12.2 Terminal design and location
       12.3 Inspection
       12.4 Selection and installation of compatible appliances
       12.5 Commissioning
       12.6 Maintenance
    13 Special categories of chimney
       13.1 Chimneys for Type C[7] ("Vertex") appliances
       13.2 Other open flue fanned draught chimneys
    Annexes
    Annex A (informative) Classifications
    Annex B (informative) Calculation method for flue sizing
    Annex C (normative) Chimney outlet positions
    Annex D (informative) Guidance on the design and installation of
                          flue block systems in the UK
    Annex E (informative) Checking of case seals and the general
                          integrity of room-sealed fan assisted positive
                          pressure gas appliances
    Annex F (normative) Design criteria for terminals for shared system
                        chimneys
    Bibliography

    Abstract - (Show below) - (Hide below)

    Defines requirements for the installation of gas appliances to chimneys, chimney installation work likely to be undertaken by gas engineers and operatives working under UK gas industry conditions and requirements for the maintenance of chimneys.

    Scope - (Show below) - (Hide below)

    This part of BS 5440 specifies requirements for the installation of gas appliances to chimneys, chimney installation work likely to be undertaken by gas engineers and operatives working under UK gas industry conditions and requirements for the maintenance of chimneys. It is applicable to open flue chimneys for Type B gas appliances and room-sealed chimney configurations for Type C gas appliances, each of rated input not exceeding 70 kW net (see Note 2 and Note 3), burning 1st, 2nd or 3rd family gases. It applies to chimneys of the natural draught or fanned draught type and is applicable to open flue chimneys and room-sealed chimneys supplied with the appliance as well as to those supplied separately.

    NOTE 1 Type B and Type C appliances are explained in Table A.1.

    It complements the requirements for the design, installation and commissioning of chimneys as required in BS EN 15287-1 and BS EN 15287-2 and requires extra details that are specific to the UK gas industry. This is kept in perspective by quoting some details of BS EN 15287-1 and BS EN 15287-2.

    It specifies the following:

    • requirements for the selection of the appropriate flueing option for gas appliances in the UK;
    • requirements for the installation of gas appliances to new chimneys, or chimney configurations;
    • requirements for the installation of gas appliances to existing chimneys or chimney configurations;
    • requirements for the installation of appliances which carry a CE mark and for which the manufacturer’s instructions are available to the installer;
    • requirements installation of appliances which do not carry a CE mark and used/second-hand appliances for which the manufacturer’s instructions are available to the installer.

    This part of BS 5440 is applicable to:

    • complete chimney and all chimney components from the appliance connection to the discharge point into outside air;
    • the installation of gas appliances to existing chimneys that were intended originally for appliances burning other fuels;
    • chimneys for residential park homes but not to chimneys for leisure accommodation vehicles.

    This part of BS 5440 is not applicable to gas-fired incinerators. Refer to BS 5871-3 for the installation of decorative fuel effect appliances.

    This part of BS 5440 includes compatibility of appliances installed in the UK with new chimneys designated under BS EN 1443 and with existing chimneys, including non-designated chimneys.

    NOTE 2 In the case of an individual appliance connected to a chimney the 70 kW maximum rated input relates to that appliance. In the case of more than one appliance in the same room connected to a single chimney the 70 kW maximum rated input relates to the sum of the rated inputs of all the appliances. In the case of appliances in separate dwellings connected to a shared flue in a chimney, e.g. a SE-duct or a U-duct, the 70 kW maximum rated input relates to the rated input of each individual appliance.

    NOTE 3 Installation of LPG (liquefied petroleum gas) systems in leisure accommodation vehicles is specified in BS EN 1949 and further guidance is given in the Institution of Gas Engineers and Managers publication IGE/UP/8 [9].

    NOTE 4 Installation of gas-fired hot water boilers having rated inputs exceeding 70 kW is specified in BS 6644.

    NOTE 5 The data in this British Standard refers to heat input expressed in terms of net calorific values (CV) with conversion given for natural gas gross CV quoted in brackets where appropriate. The ratio of gross heat input: net heat input is approximately 1.1:1 for natural gas propane and butane. For example, conversion of 9 kW input based on gross CV for natural gas to the equivalent net CV input is as follows: net input = 9.0/1.1 = 8.2 kW.

    General Product Information - (Show below) - (Hide below)

    Committee GSE/30
    Development Note Supersedes BS 5440-1(2000) & 07/30150793 DC. (04/2008)
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    BS 1289-1:1986 Flue blocks and masonry terminals for gas appliances Specification for precast concrete flue blocks and terminals
    BS EN 15287-1 : 2007 CHIMNEYS - DESIGN, INSTALLATION AND COMMISSIONING OF CHIMNEYS - PART 1: CHIMNEYS FOR NON-ROOMSEALED HEATING APPLIANCES
    BS EN 1806:2006 Chimneys Clay/ceramic flue blocks for single wall chimneys Requirements and test methods
    BS EN 1949 : 2011 SPECIFICATION FOR THE INSTALLATION OF LPG SYSTEMS FOR HABITATION PURPOSES IN LEISURE ACCOMMODATION VEHICLES AND ACCOMMODATION PURPOSES IN OTHER VEHICLES
    BS 7927:1998 Heating appliances for domestic applications. Portable apparatus designed to detect and measure specific combustion flue gas products. Requirements
    BS EN 1857 : 2003 CHIMNEYS - COMPONENTS - CONCRETE FLUE LINERS
    BS 7977-2:2003 Specification for safety and rational use of energy of domestic gas appliances Combined appliances. Gas fire/back boiler
    BS 7461:1991 Specification for electrically operated automatic gas shut-off valves fitted with throughput adjusters, proof of closure switches, closed position indicator switches or gas flow control
    BS EN 13384-1 : 2002 CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 1: CHIMNEYS SERVING ONE HEATING APPLIANCE
    BS EN 13384-2 : 2003 CHIMNEYS - THERMAL AND FLUID DYNAMIC CALCULATION METHODS - PART 2: CHIMNEYS SERVING MORE THAN ONE HEATING APPLIANCE
    BS 715:2005 Specification for metal flue boxes for gas-fired appliances not exceeding 20 kW
    BS 5871-4:2007 Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Independent gas-fired flueless fires, convector heaters and heating stoves of nominal heat input not exceeding 6 kW (2nd and 3rd family gases)
    BS EN 15287-2:2008 Chimneys. Design, installation and commissioning of chimneys Chimneys for roomsealed appliances
    BS EN 60079-10:2003 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas
    BS EN 1858 : 2008 CHIMNEYS - COMPONENTS - CONCRETE FLUE BLOCKS
    BS EN 161 : 2011 AUTOMATIC SHUT-OFF VALVES FOR GAS BURNERS AND GAS APPLIANCES
    BS 6896:2005 Specification for installation of gas-fired overhead radiant heaters for industrial and commercial heating (2nd and 3rd family gases)
    BS EN 1457:1999 Chimneys. Clay/ceramic flue liners. Requirements and test methods
    BS EN 50379-3:2012 Specification for portable electrical apparatus designed to measure combustion flue gas parameters of heating appliances Performance requirements for apparatus used in non-statutory servicing of gas fired heating appliances
    BS EN 1443:2003 Chimneys. General requirements
    BS EN 1856-1:2009 Chimneys. Requirements for metal chimneys System chimney products
    BS EN 1856-2:2009 Chimneys. Requirements for metal chimneys Metal flue liners and connecting flue pipes
    BS 1289:1975 Specification for precast concrete flue blocks for domestic gas appliances
    PD CEN/TR 1749:2014 European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types)
    BS 5534(2003) : 2003 CODE OF PRACTICE FOR SLATING AND TILING (INCLUDING SHINGLES)
    BS 8000-6:1990 Workmanship on building sites Code of practice for slating and tiling of roofs and claddings
    BS 5871-2:2005 Specification for the installation and maintenance of gas fires, convector heaters, fire/back boilers and decorative fuel effect gas appliances Inset live fuel effect gas fires of heat input not exceeding 15 kW, and fire/back boilers (2nd and 3rd family gases)
    BS 7967-4:2007 Carbon monoxide in dwellings and the combustion performance of gas-fired appliances Guide for using electronic portable combustion gas analysers as part of the process of servicing and maintenance of gas-fired appliances
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective