BS 5445-8:1984
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Components of automatic fire detection systems Specification for high temperature heat detectors
Hardcopy , PDF
01-06-2003
English
31-05-1984
Cooperating organizations
National foreword
Brief history
1 Object and field of application
2 Methods of test and test schedules
3 Marking
4 Response time
5 Vibration
6 Corrosion
7 Impact
8 Shock
9 Thermal shock and low ambient temperature
10 High ambient temperature
11 Variation of supply voltage
12 Insulation resistance
13 Dielectric strength
Annex A - Testing schedule for resettable detectors
Annex B - Testing schedule for non-resettable detectors
Annex C - Tests for response time
Annex D - Vibration test
Annex E - Corrosion test
Annex F - Impact test
Annex G - Shock test
Annex H - Thermal shock and low ambient temperature test
Annex J - High ambient temperature test
Annex K - Variation of supply voltage test
Annex L - Insulation resistance test
Annex M - Dielectric strength test
National particularity
National appendix Y - Publications referred to
National appendix Z - National committees responsible for this
British Standard
Requirements, test methods and performance criteria for heat sensitive (point) detectors containing a static element, that have high response temperatures.
Committee |
FSH/12
|
DevelopmentNote |
Also numbered as EN 54-8. Supersedes 79/10756 DC. (11/2007)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NFS 61 955 : 83 AMD 1 1989 | Identical |
BS 5839-1:1988 | Fire detection and alarm systems for buildings Code of practice for system design, installation and servicing |
BS 5445-7:1984 | Components of automatic fire detection systems Specification for point-type smoke detectors using scattered light, transmitted light or ionization |
BS 5446-1:1990 | Components of automatic fire alarm systems for residential premises Specification for self-contained smoke alarms and point-type smoke detectors |
BS 5908:1990 | Code of practice for fire precautions in the chemical and allied industries |
BS 5839-4:1988 | Fire detection and alarm systems for buildings Specification for control and indicating equipment |
BS 5839-6:1995 | Fire detection and alarm systems for buildings Code of practice for the design and installation of fire detection and alarm systems in dwellings |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
BS 5839-5:1988 | Fire detection and alarm systems for buildings Specification for optical beam smoke detectors |
EN 54-5:2017 | Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors |
BS 5839-8:1998 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning, and maintenance of voice alarm systems |
BS 5839-3:1988 | Fire detection and alarm systems for buildings Specification for automatic release mechanisms for certain fire protection equipment |
BS 5839-4:1988 | Fire detection and alarm systems for buildings Specification for control and indicating equipment |
BS 5839-6:2004 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings |
BS 5839-2:1983 | Fire detection and alarm systems for buildings Specification for manual call points |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
BS 5445-5:1977 | Components of automatic fire detection systems Heat sensitive detectors - point detectors containing a static element |
BS 5445-1:1977 | Components of automatic fire detection systems Introduction |
BS 1470:1987 | Specification for wrought aluminium and aluminium alloys for general engineering purposes: plate, sheet and strip |
BS 5839-9:2003 | Fire detection and alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems |
BS 5445-7:1984 | Components of automatic fire detection systems Specification for point-type smoke detectors using scattered light, transmitted light or ionization |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.